In this paper, experiments of crude oil demulsification using ultrasound, chemical demulsifier, and the combined method of ultrasound and chemical demulsifier, respectively, at different temperatures (40°C, 60°C, and 70°C) are carried out. The photos of water droplet distribution in crude oil, taken with microscopic imaging system, before and after demulsification using the above methods at 70°C are given. Research results show that the combined method of ultrasound and chemical demulsifier has the best demulsification effect, followed by chemical demulsifier. Ultrasound without using chemical demulsifier has the least demulsification effect. Furthermore, the impact of ultrasonic power, treatment time, and temperature on crude oil demulsification using the combined method of ultrasound and chemical demulsifier is studied. Results indicate that the final dehydration rate increases with the increase of temperatures and ultrasonic power and almost does not change with the increase of ultrasonic treatment time. These important conclusions will provide the foundation for an extensive application of the combined method of ultrasound and chemical demulsifier.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nC5WD1
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου