Publication date: Available online 1 February 2017
Source:Brachytherapy
Author(s): Muhammad F. Jamaluddin, Sunita Ghosh, Michael P. Waine, Ronald S. Sloboda, Mahdi Tavakoli, John Amanie, Albert D. Murtha, Don Yee, Nawaid Usmani
PurposeThe quality of a prostate brachytherapy implant depends on the accurate placement of sources. This study quantifies the misplacement of 125I sources from the intended location using intraoperative ultrasound images.Methods and Materials125I sources were manually identified in the postimplant ultrasound images and compared to the preoperative plan. Due to the subjective nature of the identifying sources, only sources identified with high confidence were included in the analysis. Misplacements from the original intended coordinate were measured along the X, Y, and Z axes and were stratified between overall misplacements and regions of the prostate gland.ResultsA total of 1619 125I sources using 357 strands were implanted in 15 patients' prostate glands, with 1197 (74%) confidently identified for misplacement analysis. The overall mean displacement was 0.49 cm and in the X, Y, and Z direction was 0.13, 0.15, and 0.38 cm, respectively. Greater source misplacement occurred in the anterior part of the prostate gland than the posterior part of the prostate gland by a factor 1.33 (p < 0.0001). Comparing sources in the lateral vs. medial regions of the prostate, no statistically significant differences on source misplacement were observed. Comparing misplacement in the base vs. midgland vs. apex identified the greatest difference between the base and midgland by a factor of 1.29 (p < 0.0001).ConclusionsThis study has identified significant misplacement of 125I sources from their intended locations with the greatest error misplacement occurring in the Z direction. Source misplacement tends to occur more commonly in the anterior gland and in the base of the prostate.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kVqZg2
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT