Publication date: Available online 1 February 2017
Source:Brachytherapy
Author(s): Muhammad F. Jamaluddin, Sunita Ghosh, Michael P. Waine, Ronald S. Sloboda, Mahdi Tavakoli, John Amanie, Albert D. Murtha, Don Yee, Nawaid Usmani
PurposeThe quality of a prostate brachytherapy implant depends on the accurate placement of sources. This study quantifies the misplacement of 125I sources from the intended location using intraoperative ultrasound images.Methods and Materials125I sources were manually identified in the postimplant ultrasound images and compared to the preoperative plan. Due to the subjective nature of the identifying sources, only sources identified with high confidence were included in the analysis. Misplacements from the original intended coordinate were measured along the X, Y, and Z axes and were stratified between overall misplacements and regions of the prostate gland.ResultsA total of 1619 125I sources using 357 strands were implanted in 15 patients' prostate glands, with 1197 (74%) confidently identified for misplacement analysis. The overall mean displacement was 0.49 cm and in the X, Y, and Z direction was 0.13, 0.15, and 0.38 cm, respectively. Greater source misplacement occurred in the anterior part of the prostate gland than the posterior part of the prostate gland by a factor 1.33 (p < 0.0001). Comparing sources in the lateral vs. medial regions of the prostate, no statistically significant differences on source misplacement were observed. Comparing misplacement in the base vs. midgland vs. apex identified the greatest difference between the base and midgland by a factor of 1.29 (p < 0.0001).ConclusionsThis study has identified significant misplacement of 125I sources from their intended locations with the greatest error misplacement occurring in the Z direction. Source misplacement tends to occur more commonly in the anterior gland and in the base of the prostate.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kVqZg2
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
Geographic region: Does it matter in cutaneous melanoma of the head and neck? Laryngoscope. 2017 Jun 05;: Authors: Kılıç S, Unsal AA,...
-
The overall objective of the guideline is to provide up-to-date, evidence-based recommendations for the management of lichen sclerosus (LS)...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
-
Objective. We compared the effects of transcranial direct current stimulation at different cortical sites (premotor and motor primary cortex...
-
Background. Globally 3 to 8% of reproductive age women are suffering from premenstrual dysphoric disorder (PMDD). Several mental and reprodu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου