The geometrical modelling of the planar energy diffusion behaviors of the deformations on a para-aramid fabric has been performed. In the application process of the study, in the experimental period, drop test with bullets of different weights has been applied. The B-spline curve-generating technique has been used in the study. This is an efficient method for geometrical modelling of the deformation diffusion areas formed after the drop test. Proper control points have been chosen to be able to draw the borders of the diffusion areas on the fabric which is deformed, and then the De Casteljau and De Boor algorithms have been used. The Holditch area calculation according to the beams taken at certain fixed lengths has been performed for the B-spline border curve obtained as a closed form. After the calculations, it has been determined that the diffusion area where the bullet with pointed end was dropped on a para-aramid fabric is bigger and the diffusion area where the bullet with rounded end was dropped is smaller when compared with the areas where other bullets with different ends were dropped.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kXOcxH
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Sensory Topography of Oral Structures. JAMA Otolaryngol Head Neck Surg. 2016 Sep 29; Authors: Bearelly S, Cheung SW Abstract Import...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου