Background. Very few performance-based measures used in occupational therapy have established test-retest reliability coefficients. Objectives of Study. This study presents the test-retest reliability of the task and operation scores of a performance-based measure of independence in everyday activities called the ADL Profile. Methods. 20 adults with severe traumatic brain injury (mean age 28.4 years; SD 9.9) were tested on two occasions with the 17 tasks (personal care, home, and community) of the ADL Profile. Kappa coefficients were calculated on both task and operation scores (formulating goal, planning, executing, and goal attainment). Findings. Test-retest reliability was moderate to almost perfect on task and operation scores of all 17 tasks. The three tasks with only moderate agreement were more novel and complex (e.g., making a budget) for the participants. Relevance to Clinical Practice. Use of measures that are stable over time is essential for treatment planning and research. Repeat testing is crucial with clients that require long periods of treatment (acute care, rehabilitation, and community integration) and multiple measurements of ADL independence. Limitations. The small sample size is a limit of the study. Recommendations for Further Research. Alternate versions of the three tasks with only moderate agreement would need to be developed and other psychometric properties established.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jkA8NN
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου