Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is (). The phase shift calculated for the maximum correlation is equal to ° (). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jukkau
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-...
-
by Rebekah L. Rogers, Ling Shao, Kevin R. Thornton One common hypothesis to explain the impacts of tandem duplications is that whole gene ...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2juls25 via IFTTT
-
by Qi Quan, Lei Hong, Biao Chang, Ruoxi Liu, Yun Zhu, Jiang Peng, Qing Zhao, Shibi Lu Purpose The purpose of this study was to simulate and...
-
A critical step in cellular-trafficking pathways is the budding of membranes by protein coats, which recent experiments have demonstrated ca...
-
by Mark A. Valasek, Irene Thung, Esha Gollapalle, Alexey A. Hodkoff, Kaitlyn J. Kelly, Joel M. Baumgartner, Vera Vavinskaya, Grace Y. Lin, A...
-
The secondary channel (SC) of multisubunit RNA polymerases (RNAPs) allows access to the active site and is a nexus for the regulation of tra...
-
A phase 1 dose-escalation and expansion study of binimetinib (MEK162), a potent and selective oral MEK1/2 inhibitor British Journal of Canc...
-
ACS Nano DOI: 10.1021/acsnano.6b06114 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kOsUGq via...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου