<span class="paragraphSection"><div class="boxTitle">Aims</div>The intermediate-term incidence of strut malapposition (SM) and uncovered struts (US), and the degree of neointimal thickness (NIT) according to stent type have not been characterized.<div class="boxTitle">Methods and results</div>All studies of >50 patients in which optical coherence tomography was performed between 6 and 12 months after stent implantation were included. The incidences of SM and US were the co-primary end points, while NIT was the secondary end point. A total of 458 citations were initially appraised at the abstract level, and 11 full-text studies (280 652 analysed struts, 921 patients) were assessed. The 6–12 months incidences of SM and US were 5.0 and 7.8%, respectively, and the mean NIT was 206 μm. Biolimus-eluting stents (BES) and bioresorbable vascular scaffolds (BVS) had the highest SM rates (2.7 and 3.8%, respectively), while everolimus-eluting stents (EES) and fast-release zotarolimus-eluting stents (ZES) had the lowest SM rates (0.9 and 0.1%, respectively). BES and sirolimus-eluting stents (SES) had the highest US rates (7.7 and 8.8%, respectively), while bare metal stents (BMS) and ZES had the lowest US rates (0.3 and 0.3%, respectively). BMS had the greatest NIT (340 μm), while SES, EES, and BES had the least NIT.<div class="boxTitle">Conclusion</div>Second-generation drug-eluting stents (DES) have better intermediate-term strut apposition and coverage than first-generation DES, BVS, and BMS. EES demonstrate the overall best combination of healing with suppression of neointimal hyperplasia at 6–12 months. Further studies with clinical correlation are warranted to determine the implications of these findings.</span>
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kwjvD4
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
You know the feeling: you're hanging out somewhere, you look across the room, and suddenly your stomach drops. You start to sweat. Your ...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2o7K1Dm via IFTTT
-
Inflatable Penile Prosthesis | Malleable Penile Prosthesis Implant Surgery with Penis Enlargement Phalloplasty from #AlexandrosSfakianakis...
-
What is now Middlesex University was originally a vision for a People's University: A polytechnic that would unite science, society and ...
-
About IRF. The Incentive Research Foundation (IRF), a private not-for-profit foundation, funds research studies and develops products servin...
-
Zusammenfassung Klinisches/methodisches Problem Akquisitionen in der Computertomographie (CT) sollten immer nach dem ALARA-Prinzip („as ...
-
University of sydney essay writing guide - professional writers, top-notch services, instant delivery and other advantages can be found in o...
-
We Are a Leadership Development Company. Harvard Business Publishing Corporate Learning partners with clients to create world-class leadersh...
-
9781421620831 1421620839 Coral Reef 2008 Square Wall - Wall 9780160782732 0160782732 Code of Federal Regulations, Title 27, Alcohol, Tobacco...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου