Publication date: Available online 4 April 2018
Source:European Journal of Radiology
Author(s): Osamu Honda, Masahiro Yanagawa, Akinori Hata, Noriko Kikuchi, Tomo Miyata, Shinsuke Tsukagoshi, Ayumi Uranishi, Noriyuki Tomiyama
ObjectivesTo investigate the image quality of helical scan (HS) mode and non-helical scan (non-HS) mode on ultra-high-resolution CT in different gantry rotation time.Methods Ultra-high resolution CT scanned eleven cadaveric lungs with the following rotation time with tube current of 200 mA and 0.25 mm collimation: HS with 1.5 s/rot (HS200 mA/1.5 s), non-HS with 1.5 s/rot (non-HS200 mA/1.5s), non-HS with 0.75s/rot (non-HS200 mA/0.75 s), non-HS with 0.35 s/rot (non-HS200 mA/0.35 s). Three observers compared each non-HS image with HS image, and scored non-HS images by using 3-point scale, paying attention to normal findings, abnormal findings, noise, streak artifact, and overall image quality. Statistical analysis was performed with Steel-Dwass test.ResultsOverall image quality (score: 2.45) and noise (score: 2.42) of non-HS 200 mA/1.5s was statistically best (p < 0.0005). Overall Image quality and noise of non-HS200 mA/0.75 s (score: 2.0) was comparable to that of HS200 mA/1.5 s. CTDIvol of HS200 mA/1.5 s is 23.2 mGy. CTDIvol of non-HS200 mA/1.5 s, non-HS200 mA/0.75 s, non-HS200 mA/0.35 s is 19.2 mGy, 9.8 mGy, 4.7 mGy.ConclusionOverall image quality and noise of non-helical scan is better than that of helical scan in the same rotation time. Overall Image quality of non-HS200 mA/0.75 s is comparable to that of HS200 mA/1.5 s, though the radiation dose of non-HS200 mA/0.75 s is lower than that of HS200 mA/1.5 s.
from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2qyobJn
Σάββατο 14 Απριλίου 2018
Influence of gantry rotation time and scan mode on image quality in ultra-high-resolution CT system
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Purpose To test the effects of 4 weeks of unilateral low-load resistance training (LLRT), with and without blood flow restricti...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2juls25 via IFTTT
-
Swedish medical imaging software developer SyntheticMR has received the CE... Read more on AuntMinnieEurope.com Related Reading: Siemen...
-
Long-term clinical outcomes and economic evaluation of the ketogenic diet versus care as usual in children and adolescents with intract...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qoeMDm via IFTTT
-
by Luanluan Li, Li Hua, Yafang He, Yixiao Bao Epidemiological evidence suggests that formaldehyde (FA) exposure may influence the prevalenc...
-
Relativistic hydrodynamics has been quite successful in explaining the collective behaviour of the QCD matter produced in high energy heavy-...
-
ACS Nano DOI: 10.1021/acsnano.6b06114 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kOsUGq via...
-
Immunotherapy for metastatic melanoma has a decades-long history, and the relatively recent use of checkpoint inhibitors has revolutionized...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου