Publication date: Available online 27 March 2018
Source:Academic Radiology
Author(s): Gianluca Pontone, Giuseppe Muscogiuri, Daniele Andreini, Andrea I. Guaricci, Marco Guglielmo, Andrea Baggiano, Fabio Fazzari, Saima Mushtaq, Edoardo Conte, Andrea Annoni, Alberto Formenti, Elisabetta Mancini, Massimo Verdecchia, Alessandro Campari, Chiara Martini, Marco Gatti, Laura Fusini, Lorenzo Bonfanti, Elisa Consiglio, Mark G. Rabbat, Antonio L. Bartorelli, Mauro Pepi
Rationale and objectivesA new postprocessing algorithm named adaptive statistical iterative reconstruction (ASIR)-V has been recently introduced. The aim of this article was to analyze the impact of ASIR-V algorithm on signal, noise, and image quality of coronary computed tomography angiography.Materials and MethodsFifty consecutive patients underwent clinically indicated coronary computed tomography angiography (Revolution CT; GE Healthcare, Milwaukee, WI). Images were reconstructed using filtered back projection and ASIR-V 0%, and a combination of filtered back projection and ASIR-V 20%–80% and ASIR-V 100%. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for left main coronary artery (LM), left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA) and were compared between the different postprocessing algorithms used. Similarly a four-point Likert image quality score of coronary segments was graded for each dataset and compared. A cutoff value of P < .05 was considered statistically significant.ResultsCompared to ASIR-V 0%, ASIR-V 100% demonstrated a significant reduction of image noise in all coronaries (P < .01). Compared to ASIR-V 0%, SNR was significantly higher with ASIR-V 60% in LM (P < .01), LAD (P < .05), LCX (P < .05), and RCA (P < .01). Compared to ASIR-V 0%, CNR for ASIR-V ≥60% was significantly improved in LM (P < .01), LAD (P < .05), and RCA (P < .01), whereas LCX demonstrated a significant improvement with ASIR-V ≥80%. ASIR-V 60% had significantly better Likert image quality scores compared to ASIR-V 0% in segment-, vessel-, and patient-based analyses (P < .01).ConclusionsReconstruction with ASIR-V 60% provides the optimal balance between image noise, SNR, CNR, and image quality.
from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2uu91tP
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Objective To evaluate Chinese medicine (CM) formula Bazheng Powder (八正散) as an alternative therapeutic option for female patients...
-
To evaluate the effect of Recurrence Score® results (RS; Oncotype DX® multigene assay ODX) on treatment recommendations by Swiss multidiscip...
-
Abstract Soil conditioners can be used to compensate for the insufficient soil nutrition and organic matter (OM) of arable soils. However, ...
-
Ocular Vestibular Evoked Myogenic Potentials: Where Are We Now? Objective: Over the last decade, ocular vestibular evoked myogenic potential...
-
Abstract Objective To study the effects of Astragalus polysaccharide (APS), the primary effective component of the Chinese herb medicine A...
-
Geriatric trauma: A population-based study Saint Shiou-Sheng Chen, Li-Chien Chien Formosan Journal of Surgery 2019 52(2):39-44 Background: G...
-
Objectives Adult sagittal posture is established during childhood and adolescence. A flattened or hypercurved spine is associated with poore...
-
Related Articles Screening for Atrial Fibrillation using Economical and accurate TechnologY (SAFETY)-a pilot study. BMJ Open. 2017 Ja...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου