Intense vibration affects the pore water pressure in a tailing dam, with the tendency to induce dam liquefaction. In this study, experiments were performed wherein model tailing dams were completely liquefied by sustained horizontal dynamic loading to determine the effects of the vibration frequency, vibration amplitude, and tailing density on the pore water pressure. The results revealed four stages in the increase of the tailing pore water pressure under dynamic loading, namely, a slow increase, a rapid increase, inducement of structural failure, and inducement of complete liquefaction. A lower frequency and smaller amplitude of the vibration were found to increase the time required to achieve a given pore water pressure in dense tailings. Under the effect of these three factors—vibration frequency and amplitude and tailing density—the tailing liquefaction time varied nonlinearly with the height from the base of the tailing dam, with an initial decrease followed by an increase. The pore pressure that induced structural failure also gradually decreased with increasing height. The increase in the tailing pore pressure could be described by an S-shaped model. A complementary multivariate nonlinear equation was also derived for predicting the tailing pore water pressure under dynamic loading.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nlexsK
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου