The aim of the present in vitro study was the evaluation of the fluid dynamical performance of the Carpentier-Edwards PERIMOUNT Magna Ease depending on the prosthetic size (21, 23, and 25 mm) and the cardiac output (3.6–6.4 L/min). A self-constructed flow channel in combination with particle image velocimetry (PIV) enabled precise results with high reproducibility, focus on maximal and local peek velocities, strain, and velocity gradients. These flow parameters allow insights into the generation of forces that act on blood cells and the aortic wall. The results showed that the 21 and 23 mm valves have a quite similar performance. Maximal velocities were and m/s; maximal strain , and 1/s; maximal velocity gradient , 1/s and 1/s. The 25 mm size revealed significantly lower values: maximal velocity, m/s; maximal strain , 1/s; maximal velocity gradient , 1/s. In summary, the 25 mm Magna Ease was able to create a wider, more homogenous flow with lower peak velocities especially for higher flow rates. Despite the wider flow, the velocity values close to the aortic walls did not exceed the level of the smaller valves.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2CPx6uw
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that pub...
-
You could soon get an even more immersive VR experience thanks to the Ambiotherm plug in, which exposes you to the elements of your virtual...
-
Abstract T cell immunoglobulin and mucin domain 3 (Tim-3) is a critical regulatory molecule found on activated Th1 cells, exhausted CD8 + ...
-
Join in on the conversation about GCSE Statistics Coursework Help on the TSR community forums. from #AlexandrosSfakianakis via Alexandros ...
-
CFS, also known as ME, may be caused by the body switching from fully breaking down carbohydrates to using other energy sources, bringing o...
-
Study of Sharp Corner Cutting In Wire EDM Thesis submitted in accordance with The test specimens have been cut by using different wire-cut E...
-
Visit this site dedicated to Valentine from 100 Valentine Poems for your special person. Famous Valentine Poems from the Worlds greatest Poe...
-
Planta Med DOI: 10.1055/s-0043-106050 Glucose homeostasis is maintained by antagonistic hormones such as insulin and glucagon as well as ...
-
Cancerous tumours are voracious. Once they have consumed all the oxygen and nutrients in the original tumour site, the cancer cells travel t...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου