In view of the speed sensor faults in elevating stage control system, an active fault tolerant control approach based on a novel tracking differentiator is proposed in this paper. First, the analytical redundancy relationship between the velocity and displacement signals in a dual closed loop control system is used to detect a fault. When the deviation between the differential of normal displacement sensor signal and the fault speed sensor output exceeds a certain threshold value, a fault can be considered to occur. Secondly, after a fault is detected, the output of the fault sensor is replaced immediately with the differential signal of the output from a normal sensor to ensure the safety of the postfault system. In the process of signal differential, considering the drawbacks of the traditional method which uses inertial element to approximate differentiator and complex parameter tuning of Han’s Tracking Differentiator (TD), a novel tracking differentiator based on hyperbolic tangent function (Tanh-TD) is designed. Thirdly, in order to avoid the switching vibration and improve the reliability of FDD, a continuous smooth switching tactic based on exponential function is constructed. The simulation results show that the fault diagnosis method is simple and timely, the designed tracking differentiator is fast and effective, and the effect of the fault tolerant control based on smooth switching strategy is also satisfactory.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2lAzvSx
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objectives To optimise medical students’ early clerkship is a complex task since it is conducted in a context primarily organised to take ca...
-
Abstract Nano-silver and nano-titanium oxide films can be coated over brackets in order to reduce bacterial aggregation and friction. Howe...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
1 abqls-210rm.html Read the latest Journal of Clinical Neurophysiology - Vol. 37, No. 1, January 2020.eml 2 agx3v-nxz96.html Read the late...
-
Cone-beam CT (CBCT) is a widely used intra-operative imaging modality in image-guided radiotherapy and surgery. A short scan followed by a f...
-
by Yanwei Li, Haifeng Liu, Wei Zeng, Jing Wei An increase in the osmolarity of tears induced by excessive evaporation of the aqueous tear p...
-
http://ift.tt/2p41efZ
-
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου