Publication date: Available online 11 December 2017
Source:European Journal of Radiology
Author(s): Tilman Hickethier, Jonathan Byrtus, Myriam Hauger, Andra-Iza Iuga, Gregor Pahn, David Maintz, Stefan Haneder, Jonas Doerner
ObjectivesTo investigate the utilization of virtual mono-energetic images (MonoE) at low kiloelectron volt (keV) levels derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans using arterial phase imaging as an internal reference standard.Materials and MethodsA total of 50 patients who received arterial and venous phase imaging of the abdomen on a SDCT system were included in this study. Absolute attenuation, noise, signal- and contrast to noise ratios (SNR; CNR) as well as arterial diameters in defined landmarks were assessed. In arterial phase, conventional reconstructions (CRART) as well as MonoEART at 40keV and in venous phase, conventional reconstructions (CRVEN) as well as MonoEVEN at 70 and 40keV were investigated and intra-individual comparisons were performed. If an artery stenosis (10 patients) was present, the degree of stenosis was assessed according to the system of the North American Symptomatic Carotid Endarterectomy Trial (NASCET).ResultsMonoE 40keV yielded significantly higher attenuation values (in arterial as well as in venous phase) compared to CRART (p<0.001) while noise levels were substantially low. This resulted in markedly superior SNR and CNR in large vessel compared to CRART.Luminal diameters were significantly smaller in MonoE 40keV in both contrast phases compared to CRART (p <0.001), whereas no significant differences were found between both MonoE reconstructions (p≥0.92). The degree of vessel stenosis was significantly higher in MonoE 40keV of both contrast phases compared to CRART (p≥0.02).ConclusionMonoE at low keV of venous contrast phase scans derived from a novel SDCT are suitable for the assessment of arteries in the abdomen and subsequent stenosis assessment. However, MonoE at 40keV constantly showed significant smaller luminal diameters than the corresponding conventional reconstructions (including the reference standard). This is possibly due to an improved differentiation of the vessel lumen from the wall and raises the question, which imaging technique should be used as an appropriate reference standard for vascular SDCT imaging studies.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2AcuKVz
Δευτέρα 11 Δεκεμβρίου 2017
Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
A study using a new computer-aided detection (CAD) algorithm found breast cancers... Read more on AuntMinnieEurope.com Related Reading: ...
-
Predictors of postoperative pneumonia in patients undergoing oral cancer resections and its management p. 69 Ridhi Sood, Jerry Paul, Sunil...
-
This work presents the nonlinear dynamical analysis of a multilayer piezoelectric macrofiber composite (MFC) laminated shell. The effects of...
-
The upper reaches of the Heihe River have been regarded as a hotspot for phytoecology, climate change, water resources and hydrology studies...
-
Dicyclohexyl phthalate (DCHP) is one of the phthalate plasticizers. The objective of the present study was to investigate the effects of DCH...
-
This study analyzes 24 climate extreme indices over North Thailand using observed data for daily maximum and minimum temperatures and total ...
-
<span class="paragraphSection">Much public health research seeks to identify harm and then use that knowledge as the basis f...
-
Most prescribers and patients in Ghana now opt for the relatively expensive artemether/lumefantrine rather than artesunate-amodiaquine due t...
-
Antineutrophil cytoplasmic antibody- (ANCA-) associated vasculitis (AAV) is a multisystem autoimmune disease affecting mainly microscopic bl...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου