Author(s): Tilman Hickethier, Jonathan Byrtus, Myriam Hauger, Andra-Iza Iuga, Gregor Pahn, David Maintz, Stefan Haneder, Jonas Doerner
ObjectivesTo investigate the utilization of virtual mono-energetic images (MonoE) at low kiloelectron volt (keV) levels derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans using arterial phase imaging as an internal reference standard.Materials and MethodsA total of 50 patients who received arterial and venous phase imaging of the abdomen on a SDCT system were included in this study. Absolute attenuation, noise, signal- and contrast to noise ratios (SNR; CNR) as well as arterial diameters in defined landmarks were assessed. In arterial phase, conventional reconstructions (CRART) as well as MonoEART at 40keV and in venous phase, conventional reconstructions (CRVEN) as well as MonoEVEN at 70 and 40keV were investigated and intra-individual comparisons were performed. If an artery stenosis (10 patients) was present, the degree of stenosis was assessed according to the system of the North American Symptomatic Carotid Endarterectomy Trial (NASCET).ResultsMonoE 40keV yielded significantly higher attenuation values (in arterial as well as in venous phase) compared to CRART (p<0.001) while noise levels were substantially low. This resulted in markedly superior SNR and CNR in large vessel compared to CRART.Luminal diameters were significantly smaller in MonoE 40keV in both contrast phases compared to CRART (p <0.001), whereas no significant differences were found between both MonoE reconstructions (p≥0.92). The degree of vessel stenosis was significantly higher in MonoE 40keV of both contrast phases compared to CRART (p≥0.02).ConclusionMonoE at low keV of venous contrast phase scans derived from a novel SDCT are suitable for the assessment of arteries in the abdomen and subsequent stenosis assessment. However, MonoE at 40keV constantly showed significant smaller luminal diameters than the corresponding conventional reconstructions (including the reference standard). This is possibly due to an improved differentiation of the vessel lumen from the wall and raises the question, which imaging technique should be used as an appropriate reference standard for vascular SDCT imaging studies.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2AcuKVz
Δευτέρα 11 Δεκεμβρίου 2017
Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου