Publication date: Available online 11 December 2017
Source:European Journal of Radiology
Author(s): Tilman Hickethier, Jonathan Byrtus, Myriam Hauger, Andra-Iza Iuga, Gregor Pahn, David Maintz, Stefan Haneder, Jonas Doerner
ObjectivesTo investigate the utilization of virtual mono-energetic images (MonoE) at low kiloelectron volt (keV) levels derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans using arterial phase imaging as an internal reference standard.Materials and MethodsA total of 50 patients who received arterial and venous phase imaging of the abdomen on a SDCT system were included in this study. Absolute attenuation, noise, signal- and contrast to noise ratios (SNR; CNR) as well as arterial diameters in defined landmarks were assessed. In arterial phase, conventional reconstructions (CRART) as well as MonoEART at 40keV and in venous phase, conventional reconstructions (CRVEN) as well as MonoEVEN at 70 and 40keV were investigated and intra-individual comparisons were performed. If an artery stenosis (10 patients) was present, the degree of stenosis was assessed according to the system of the North American Symptomatic Carotid Endarterectomy Trial (NASCET).ResultsMonoE 40keV yielded significantly higher attenuation values (in arterial as well as in venous phase) compared to CRART (p<0.001) while noise levels were substantially low. This resulted in markedly superior SNR and CNR in large vessel compared to CRART.Luminal diameters were significantly smaller in MonoE 40keV in both contrast phases compared to CRART (p <0.001), whereas no significant differences were found between both MonoE reconstructions (p≥0.92). The degree of vessel stenosis was significantly higher in MonoE 40keV of both contrast phases compared to CRART (p≥0.02).ConclusionMonoE at low keV of venous contrast phase scans derived from a novel SDCT are suitable for the assessment of arteries in the abdomen and subsequent stenosis assessment. However, MonoE at 40keV constantly showed significant smaller luminal diameters than the corresponding conventional reconstructions (including the reference standard). This is possibly due to an improved differentiation of the vessel lumen from the wall and raises the question, which imaging technique should be used as an appropriate reference standard for vascular SDCT imaging studies.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2AcuKVz
Δευτέρα 11 Δεκεμβρίου 2017
Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
IZE is a professional association dedicated to expanding the educational impact of zoos and aquariums worldwide, to enhance the understandin...
-
Copyright © 1999-2007 by , Kai Froeb. Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free ...
-
A Vietnam War Timeline [Note: This timeline is an abbreviated version of the more detailed timeline posted on the Public Broadcasting System...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nhPCs5 via IFTTT
-
Greens Blue Flame supplies propane tank installation services and propane delivery in the Houston, TX area. We also offer bulk commercial de...
-
4995879043233 Swing Low, Staple Singers, Stapsingers 9780340891070 0340891076 Hod Cat - Sceptre Catalogue Jul 9781560630821 1560630825 Babil...
-
1,001 FREE cover letter examples and samples for consultants, career changers, and job hunters. The FIRST and BEST cover letters on the Inte...
-
Disclaimer: All personages on drawings over 18 age. -high- has a zero-tolerance policy against illegal pornography. All content and links ar...
-
The National Booster Club Training Council, Providing Guidance, Education, Training and Support from #AlexandrosSfakianakis via Alexandros...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου