New HPLC-UV method (method A), for simultaneous determination of metformin (MET) and canagliflozin (CANA), was developed and compared to another novel UPLC-UV method (method B) in their tablet combination. Concerning method A, isocratic separation was done by C18 column (100 mm 2.1 mm, 3 m) using methanol and 0.03 M phosphate buffer (, ) at pH 3.2 as a mobile phase. Meanwhile, chromatographic separation in method B was achieved via Hypersil® gold (50 mm 2.1 mm, 1.9 m). Mobile phase was methanol and 0.03 M phosphate buffer at ratio of . In both, detection was done at wavelength of 240 nm. Method A showed satisfactory linearity results over 1–50 gmL−1 and 0.5–100 gmL−1, while method B linearity was at 0.1–50 gmL−1 and 0.25–100 gmL−1 for CANA and MET, respectively. In terms of accuracy and precision, method A accuracy was and , while method B gave accuracy of and for CANA and MET, respectively. For precision, the % RSD was found to be less than 2% for three concentrations analyzed three times. The two methods are convenient for quality laboratories, yet the UPLC method offered the advantage of shorter run times and higher sensitivity.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2khU6y4
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
CBN News Cancer Took Most of His Tongue, but This Pastor Is Still Singing ... CBN News A youth pastor in San Diego, California is not ...
-
Related Articles Audiologic and radiologic findings in cochlear hypoplasia. Auris Nasus Larynx. 2017 Jan 10;: Authors: Cinar BC, Bat...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
-
IJMS, Vol. 19, Pages 38: Recombinant Zika NS1 Protein Secreted from Vero Cells Is Efficient for Inducing Production of Immune Serum Directed...
-
Background. Globally 3 to 8% of reproductive age women are suffering from premenstrual dysphoric disorder (PMDD). Several mental and reprodu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου