New HPLC-UV method (method A), for simultaneous determination of metformin (MET) and canagliflozin (CANA), was developed and compared to another novel UPLC-UV method (method B) in their tablet combination. Concerning method A, isocratic separation was done by C18 column (100 mm 2.1 mm, 3 m) using methanol and 0.03 M phosphate buffer (, ) at pH 3.2 as a mobile phase. Meanwhile, chromatographic separation in method B was achieved via Hypersil® gold (50 mm 2.1 mm, 1.9 m). Mobile phase was methanol and 0.03 M phosphate buffer at ratio of . In both, detection was done at wavelength of 240 nm. Method A showed satisfactory linearity results over 1–50 gmL−1 and 0.5–100 gmL−1, while method B linearity was at 0.1–50 gmL−1 and 0.25–100 gmL−1 for CANA and MET, respectively. In terms of accuracy and precision, method A accuracy was and , while method B gave accuracy of and for CANA and MET, respectively. For precision, the % RSD was found to be less than 2% for three concentrations analyzed three times. The two methods are convenient for quality laboratories, yet the UPLC method offered the advantage of shorter run times and higher sensitivity.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2khU6y4
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου