Publication date: March 2018
Source:Journal of Environmental Radioactivity, Volume 183
Author(s): Xiaobing Geng, Zhenghui Xie, Lijun Zhang, Mei Xu, Binghao Jia
An inverse source estimation method is proposed to reconstruct emission rates using local air concentration sampling data. It involves the nonlinear least squares-based ensemble four-dimensional variational data assimilation (NLS-4DVar) algorithm and a transfer coefficient matrix (TCM) created using FLEXPART, a Lagrangian atmospheric dispersion model. The method was tested by twin experiments and experiments with actual Cs-137 concentrations measured around the Fukushima Daiichi Nuclear Power Plant (FDNPP). Emission rates can be reconstructed sequentially with the progression of a nuclear accident, which is important in the response to a nuclear emergency. With pseudo observations generated continuously, most of the emission rates were estimated accurately, except under conditions when the wind blew off land toward the sea and at extremely slow wind speeds near the FDNPP. Because of the long duration of accidents and variability in meteorological fields, monitoring networks composed of land stations only in a local area are unable to provide enough information to support an emergency response. The errors in the estimation compared to the real observations from the FDNPP nuclear accident stemmed from a shortage of observations, lack of data control, and an inadequate atmospheric dispersion model without improvement and appropriate meteorological data. The proposed method should be developed further to meet the requirements of a nuclear emergency response.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2kF3bhR
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT