Publication date: January 2018
Source:European Journal of Radiology, Volume 98
Author(s): Patrice Roch, David Célier, Cécile Dessaud, Cécile Etard
ObjectivesTwelve years since the implementation of Diagnostic Reference Levels (DRL) process in France, the Nuclear Safety and Radiation Protection French Institute (IRSN) presents its latest analyses performed on the most recent national data.MethodsStatutorily, each year, medical imaging departments must perform patient exposure evaluation from their clinical practice for at least 2 types of radiographic and computed tomography (CT) examinations freely chosen in the regulatory list. The samples of dosimetric data used for the evaluations must be sent to IRSN for national assessment using a dedicated and secured web portal. The analyses of collected data for radiography and CT allow IRSN to estimate the representativeness of current DRLs in terms of target practices and examinations, dosimetric quantities and numerical values. Technical data are transmitted, such as detector type in radiography or commissioning date of CT, and are included in some complementary analyses in order to evaluate their influence on patient exposure.ResultsSince 2004 the involvement of professionals in the DRL process has highly increased in CT (about 80% in 2015) but remains quite weak in radiography (almost 30%). Analyses show some discordance between regulation references and clinical practice leading to clinical doses data which are 40% lower than DRLs in 2015. As a consequence, the list of examinations types and some numerical values should be updated in the regulation.Focused analyses show a significant patient exposure reduction when digital radiography is used and when CT equipment is under five years old.ConclusionsBased on these findings, IRSN recommends to update DRL regulation with current and relevant examination lists, dosimetric quantities and numerical values. In addition, this study shows that technology and generation of equipment, such as detector type in radiography or image reconstruction algorithm in CT, take an important place in the dose optimisation process, enabling significant patient exposure reduction when it is associated with protocols optimisation.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zSwFku
Σάββατο 18 Νοεμβρίου 2017
Using diagnostic reference levels to evaluate the improvement of patient dose optimisation and the influence of recent technologies in radiography and computed tomography
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
2016-09-24T01-16-18Z Source: International Journal of Research in Medical Sciences Biswajit Majumder, Viral Tandel, Sandip Ghosh, Sharmis...
-
JPM, Vol. 8, Pages 5: Acknowledgement to Reviewers of Journal of Personalized Medicine in 2017 Journal of Personalized Medicine doi: 10.339...
-
Antibodies, Vol. 7, Pages 6: In-Depth Comparison of Lysine-Based Antibody-Drug Conjugates Prepared on Solid Support Versus in Solution Anti...
-
This paper proposes an enhanced ant colony optimization with dynamic mutation and ad hoc initialization, ACODM-I, for improving the accuracy...
-
No large-scale, head-to-head, phase III, randomized, controlled trial with an adequate sample size has investigated the effect of concurrent...
-
by Alison M. Hixon, Guixia Yu, J. Smith Leser, Shigeo Yagi, Penny Clarke, Charles Y. Chiu, Kenneth L. Tyler In 2014, the United States exp...
-
Accumulating data have indicated that citrus polymethoxyflavones (PMFs) have the ability to affect brain function. In the present study, we ...
-
ACS Nano DOI: 10.1021/acsnano.7b02426 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2h1neaG via...
-
Related Articles Long-acting insulin allergy in a diabetic child. Int J Immunopathol Pharmacol. 2017 Apr 01;:394632017700431 Authors...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου