Publication date: January 2018
Source:European Journal of Radiology, Volume 98
Author(s): Patrice Roch, David Célier, Cécile Dessaud, Cécile Etard
ObjectivesTwelve years since the implementation of Diagnostic Reference Levels (DRL) process in France, the Nuclear Safety and Radiation Protection French Institute (IRSN) presents its latest analyses performed on the most recent national data.MethodsStatutorily, each year, medical imaging departments must perform patient exposure evaluation from their clinical practice for at least 2 types of radiographic and computed tomography (CT) examinations freely chosen in the regulatory list. The samples of dosimetric data used for the evaluations must be sent to IRSN for national assessment using a dedicated and secured web portal. The analyses of collected data for radiography and CT allow IRSN to estimate the representativeness of current DRLs in terms of target practices and examinations, dosimetric quantities and numerical values. Technical data are transmitted, such as detector type in radiography or commissioning date of CT, and are included in some complementary analyses in order to evaluate their influence on patient exposure.ResultsSince 2004 the involvement of professionals in the DRL process has highly increased in CT (about 80% in 2015) but remains quite weak in radiography (almost 30%). Analyses show some discordance between regulation references and clinical practice leading to clinical doses data which are 40% lower than DRLs in 2015. As a consequence, the list of examinations types and some numerical values should be updated in the regulation.Focused analyses show a significant patient exposure reduction when digital radiography is used and when CT equipment is under five years old.ConclusionsBased on these findings, IRSN recommends to update DRL regulation with current and relevant examination lists, dosimetric quantities and numerical values. In addition, this study shows that technology and generation of equipment, such as detector type in radiography or image reconstruction algorithm in CT, take an important place in the dose optimisation process, enabling significant patient exposure reduction when it is associated with protocols optimisation.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zSwFku
Σάββατο 18 Νοεμβρίου 2017
Using diagnostic reference levels to evaluate the improvement of patient dose optimisation and the influence of recent technologies in radiography and computed tomography
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
IZE is a professional association dedicated to expanding the educational impact of zoos and aquariums worldwide, to enhance the understandin...
-
Copyright © 1999-2007 by , Kai Froeb. Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free ...
-
A Vietnam War Timeline [Note: This timeline is an abbreviated version of the more detailed timeline posted on the Public Broadcasting System...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nhPCs5 via IFTTT
-
Greens Blue Flame supplies propane tank installation services and propane delivery in the Houston, TX area. We also offer bulk commercial de...
-
4995879043233 Swing Low, Staple Singers, Stapsingers 9780340891070 0340891076 Hod Cat - Sceptre Catalogue Jul 9781560630821 1560630825 Babil...
-
Disclaimer: All personages on drawings over 18 age. -high- has a zero-tolerance policy against illegal pornography. All content and links ar...
-
1,001 FREE cover letter examples and samples for consultants, career changers, and job hunters. The FIRST and BEST cover letters on the Inte...
-
The National Booster Club Training Council, Providing Guidance, Education, Training and Support from #AlexandrosSfakianakis via Alexandros...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου