Publication date: January 2018
Source:European Journal of Radiology, Volume 98
Author(s): Patrice Roch, David Célier, Cécile Dessaud, Cécile Etard
ObjectivesTwelve years since the implementation of Diagnostic Reference Levels (DRL) process in France, the Nuclear Safety and Radiation Protection French Institute (IRSN) presents its latest analyses performed on the most recent national data.MethodsStatutorily, each year, medical imaging departments must perform patient exposure evaluation from their clinical practice for at least 2 types of radiographic and computed tomography (CT) examinations freely chosen in the regulatory list. The samples of dosimetric data used for the evaluations must be sent to IRSN for national assessment using a dedicated and secured web portal. The analyses of collected data for radiography and CT allow IRSN to estimate the representativeness of current DRLs in terms of target practices and examinations, dosimetric quantities and numerical values. Technical data are transmitted, such as detector type in radiography or commissioning date of CT, and are included in some complementary analyses in order to evaluate their influence on patient exposure.ResultsSince 2004 the involvement of professionals in the DRL process has highly increased in CT (about 80% in 2015) but remains quite weak in radiography (almost 30%). Analyses show some discordance between regulation references and clinical practice leading to clinical doses data which are 40% lower than DRLs in 2015. As a consequence, the list of examinations types and some numerical values should be updated in the regulation.Focused analyses show a significant patient exposure reduction when digital radiography is used and when CT equipment is under five years old.ConclusionsBased on these findings, IRSN recommends to update DRL regulation with current and relevant examination lists, dosimetric quantities and numerical values. In addition, this study shows that technology and generation of equipment, such as detector type in radiography or image reconstruction algorithm in CT, take an important place in the dose optimisation process, enabling significant patient exposure reduction when it is associated with protocols optimisation.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zSwFku
Σάββατο 18 Νοεμβρίου 2017
Using diagnostic reference levels to evaluate the improvement of patient dose optimisation and the influence of recent technologies in radiography and computed tomography
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Pulmonary complications post hematopoietic stem cell transplant in dyskeratosis congenita: analysis of oxidative stress in lung fibrobl...
-
guide to thesis writing guide to thesis writing College Application Essay Pay Jmu Use your free time to prepare for an exam or meet with fri...
-
Abstract Background We have previously published data from 2001 to 2006 showing that adolescent and young adult (AYA) oncology patients ...
-
by Mindaugas Paužuolis, Torsten Eich, Joachim Burman Background Natalizumab (NTZ) is a drug that has been widely used in the treatment of m...
-
REM sleep selectively prunes and maintains new synapses in development and learning. Nat Neurosci. 2017 Jan 16;: Authors: Li W, Ma L,...
-
Abstract Desmoplastic small round cell tumor (DSCRT) is a rare malignancy most often seen in the abdomen or pelvis of young men. Unfortuna...
-
Abstract Purpose To develop the first photoactive biomaterial coating capable of controlled drug dosing via inclusion of synthesised drug-...
-
A U.K.-based radiology website, Radiology Café, is offering a free collection... Read more on AuntMinnieEurope.com Related Reading: RCR...
-
Essay Example, Outline, and Introduction Sample Here are the instructions you will see for the essay outline and introduction section of the...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου