Abstract
Aim
This study assessed safety and efficacy associated with hernia prophylaxis using a retromuscular slowly resorbable synthetic mesh for stoma reinforcement.
Method
This was a cohort study with a historic reference group. The study took place in a high-volume surgical department. During a 2-year period (July 2012–July 2014), we included 109 patients undergoing emergency surgery with formation of ileostomy or colostomy. All patients received a retromuscular slowly resorbable synthetic mesh (TIGR®, Novus Scientific) at the stoma site. The reference group included 117 patients who underwent emergency stoma formation without a prophylactic mesh in the 2-year period prior to July 2012. The primary endpoint was effect on prevention of parastomal hernia within 1 year. Secondary endpoints were 30-day and 1-year complications including mortality.
Results
The operative field was contaminated or dirty in 48% of the procedures. Operative time was significantly longer in the mesh group. The cumulative incidences of parastomal hernia at 1 year for the control and the mesh group were 8 and 7% (p = 0.424), respectively. The postoperative 30-day and 1-year rate of complications, reoperations and mortality were not different between the two groups. No patients underwent removal of the mesh and no clinical mesh infections were seen.
Conclusion
Use of a resorbable synthetic mesh during emergency ostomy formation showed no significant preventive effect on formation of parastomal hernia after 1 year. Although surgery was often conducted in a severely contaminated field, the procedure was without significantly increased complication rate.