Publication date: Available online 5 May 2017
Source:Journal of Biomechanics
Author(s): Hamidreza Alidousti, Neil W. Bressloff
Osteolysis around joint replacements may develop due to migration of wear particles from the joint space into gaps between the interface bone and the implant where they can accumulate in high concentrations to cause tissue damage. Osteolysis may appear in various postoperative times and morphological shapes which can be generalized into linear and focal. However, there are no clear explanations on the causes of such variations. Patients’ degree of sensitivity to polyethylene particles (osteolysis thresholds), the local particle concentration and the access route provided by the interface gaps have been described as determining factors. To study their effects, a 2D computational fluid dynamics model of the hip joint capsule in communication with an interfacial gap and the surrounding bone was employed. Particles were presented using a discrete phase model (DPM). High capsular fluid pressure was considered as the driving force for particle migration. Simulations were run for different osteolysis thresholds ranging from 5 ×108 to 1 ×1012 particle number per gram of tissue and fibrous tissue generation in osteolytic lesion due to particles was simulated for the equivalent of ten postoperative years. In patients less sensative to polyethylene particles (higher threshold), osteolysis may be linear and occur along an interfacial gap in less than 5% of the interfatial tissue. Focal osteolysis is more likely to develop in patients with higher sensitivity to polyethylene particles at distal regions to an interfacial gaps where up to 80% of the interfatial tissue may be replaced by fibrous tissue. In these patients, signs of osteolysis may also develop earlier (third postoperative year) than those with less sensitivity who may show very minor signs even after ten years. This study shows the importance of patient sensitivity to wear particles, the role of interfatial gaps in relation to morphology and the onset of osteolysis. Consequently, it may explain the clinically observed variation in osteolysis development.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pQ6Dta
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
UM-Chor1: establishment and characterization of the first validated clival chordoma cell line. J Neurosurg. 2017 Apr 21;:1-9 Authors:...
-
Publication date: Available online 10 May 2017 Source: Journal of Dairy Science Author(s): R.E. Vibart, M. Tavendale, D. Otter, B.H. Schw...
-
Abstract Introduction In hypo-albuminemia, the extent of albumin binding of a drug decreases. The resulting change in plasma protein bin...
-
Abstract Inadequate post-operative pain management can have significant impacts on patients' quality of life. Effective management of ...
-
Abstract Background Cancer patients suffer in part because some health professionals prescribe or administer amounts of analgesics, namely...
-
Abstract Purpose Studies on preemptive analgesia in maxillofacial surgery have shown several controversial clinical results, mainly due to...
-
Special Issue for Papers Presented at the Annual Meeting of the German Audiology and Neurootology Group 2014 (ADANO) in Dresden/Germany No a...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου