Publication date: Available online 5 May 2017
Source:Clinical Biochemistry
Author(s): Joyce Matie Kinoshita da Silva-Etto, Rejane Mattar, Cibele Aparecida Villares-Lopes, Sergio Barbosa Marques, Flair José Carrilho
ObjectivesThe stool antigen assay for H. pylori infection diagnosis with monoclonal antibodies is a simple and recommended technique by the Maastricht V/Florence consensus report. Recently, Pylori K-Set K-1219 (Coris Bioconcept Sprl, Belgium) and HP-F23 (Symbiosys, Brazil) have been made commercially available in Brazil. Thus, the aim of this study was to evaluate the diagnostic accuracies of these two rapid stool antigen tests by immunochromatographic assays (index tests) for the clinical practice.Design and methodsA total of 98 patients who underwent upper gastrointestinal endoscopy and 13C-urea breath test entered the study. H. pylori infection status was defined by the combination of the rapid urease test and the 13C-urea breath test (reference standard). Two observers who were aware of H. pylori status performed the reading of index tests. Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value with 95% confidence intervals, positive likelihood ratio, negative likelihood ratio and kappa index measure of agreement) were determined.ResultsThe index tests where in perfect agreement with the H. pylori status with kappa values of 0.87 for Pylori K-Set K-1219 and 0.92 for HP-F23. The sensitivity of HP-F23 was 97.9% (IC95%: 87.5–100) and specificity was 93.8% (IC95%; 84–97.2).The positive likelihood ratio was 15.8, and the negative likelihood ratio was 0.02. The Pylori K-Set K-1219 had a sensitivity of 87.7% (IC95%: 74.5–94.9) and a specificity of 100% (IC95%: 91.6–100); the positive likelihood ratio was ∞, and the negative likelihood ratio was 0.1. The test line on the cassette device of HP-F23 was stronger than of the Pylori K-Set K-1219.ConclusionThe HP-F23 test performed better in clinical practice. Nonetheless, the 13C-urea breath test is more reliable technique. Moreover, caution must be paid to the trace or clear pale test line readings that were observed in false positive and false negative results, leading to incorrect management of the patient.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pk0nHa
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
ACS Nano DOI: 10.1021/acsnano.6b04244 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2aOZU8w via...
-
JOURNAL OF JAPAN SOCIETY FOR SAFETY ENGINEERING_1998_5 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt...
-
-
Vol.83 No.3 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1TkQfWM via IFTTT
-
Small size of metastatic lymph nodes with extracapsular spread greatly impacts treatment outcomes in oral squamous cell carcinoma patie...
-
Guidelines for inpatient admission after pediatric tonsillectomy have been proposed to improve the safety of this procedure. This study exam...
-
Madhavi Bhargava Journal of Family and Community Medicine 2017 24(2):131-131 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis ...
-
Publication date: Available online 14 May 2017 Source: Journal of Oral Biosciences Author(s): Hiromi Kimura-Suda, Teppi Ito BackgroundBo...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου