Publication date: July 2017
Source:International Journal of Pediatric Otorhinolaryngology, Volume 98
Author(s): Kahren K. Aydinyan, Jonathan D. Day, Gina M. Troiano, G. Paul Digoy
ObjectivesTo present our experience with two methods of neck stabilization after pediatric tracheal resection with primary anastomosis as possible alternatives to the traditional chest-chin suture.MethodsChildren undergoing tracheal resection and/or cricotracheal resection with anastomosis under tension were placed in cervical spine flexion postoperatively with either a chest-chin (Grillo) suture, an Aspen cervical collar or Trulife Johnson cervical-thoracic orthosis (CTO). A retrospective chart review of tracheal resections performed between 2005 and 2016 was completed to evaluate the positive and negative factors associated with each neck flexion technique.ResultsOf the 20 patients, there were 13 patients with the Grillo suture, 4 with the Aspen collar and 3 patients with the Johnson CTO. There were 13 tracheal resection procedures and 7 cricotracheal resections, all of which had anastomosis under tension. One major anastomosis dehiscence was noted with the Grillo suture technique which required reoperation. Two patients with the Grillo suture experienced skin breakdown at the suture site. The Aspen cervical collar, which fixed the cervical spine and prevented lateral and rotational motion, was limited in several cases in that it placed the spine in slight hyperextension. The Johnson CTO provided the most support in a flexed position and prevented cervical spine motion in all directions. No anastomosis complications were noted with the Aspen collar or the Johnson CTO, however, several patients sustained minor cutaneous wounds.ConclusionIn this series the Aspen cervical collar and Johnson CTO were used successfully as non-Grillo alternatives to postoperative neck stabilization in pediatric tracheal resections. Modifications to both devices are proposed to minimize cutaneous injuries and increase immobilization of the cervical spine in the desired flexed position. Although these devices appear to be safe and may be better tolerated, further innovation is needed to improve the design and fit of these devices.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2raU0HH
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
When you make pizza this good you are allowed to brag about it. Come try a square of the best pizza in Erie. Ohhh yeah, we have ice cream no...
-
The trehalose biosynthetic pathway is of great interest for the development of novel therapeutics because trehalose is an essential disaccha...
-
British Journal of Oral and Maxillofacial Surgery... Stem Cells and DevelopmentMesenchymal Stem/Stroma... [ASAP] Self-Assembly of Giant Mo...
-
Abstract ᅟ http://ift.tt/2pGNeby
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2o6Gupp via IFTTT
-
The efficacy and optimization of poststroke physical therapy paradigms is challenged in part by a lack of objective tools available to resea...
-
Robert Schumann regnes som en av de store romantiske komponistene, særlig anerkjent er hans klaver- og kammermusikk. Han startet på utdanni...
-
Abstract Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility o...
-
Background. There have not yet been any studies to validate the intubation difficulty scale (IDS) in obese parturients. Objectives of this s...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου