The precast concrete (PC) method used in the construction process of high technology industrial facilities is limited when applied to those with greater span lengths, due to the transport length restriction (maximum length of 15~16 m in Korea) set by traffic laws. In order to resolve this, this study introduces a structural system with a segmented PC system, and a 1/2 scale model with a width of 9000 mm (hereafter Segmented Model) is manufactured to evaluate vibration performance. Since a real vibrational environment cannot be reproduced for vibration testing using a scale model, a comparative analysis of their relative performances is conducted in this study. For this purpose, a 1/2 scale model with a width of 7200 mm (hereafter Nonsegmented Model) of a high technology industrial facility is additionally prepared using the conventional PC method. By applying the same experiment method for both scale models and comparing the results, the relative vibration performance of the Segmented Model is observed. Through impact testing, the natural frequencies of the two scale models are compared. Also, in order to analyze the estimated response induced by the equipment, the vibration responses due to the exciter are compared. The experimental results show that the Segmented Model exhibits similar or superior performances when compared to the Nonsegmented Model.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kFLGOR
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that pub...
-
You could soon get an even more immersive VR experience thanks to the Ambiotherm plug in, which exposes you to the elements of your virtual...
-
Abstract T cell immunoglobulin and mucin domain 3 (Tim-3) is a critical regulatory molecule found on activated Th1 cells, exhausted CD8 + ...
-
Join in on the conversation about GCSE Statistics Coursework Help on the TSR community forums. from #AlexandrosSfakianakis via Alexandros ...
-
CFS, also known as ME, may be caused by the body switching from fully breaking down carbohydrates to using other energy sources, bringing o...
-
Study of Sharp Corner Cutting In Wire EDM Thesis submitted in accordance with The test specimens have been cut by using different wire-cut E...
-
Visit this site dedicated to Valentine from 100 Valentine Poems for your special person. Famous Valentine Poems from the Worlds greatest Poe...
-
Planta Med DOI: 10.1055/s-0043-106050 Glucose homeostasis is maintained by antagonistic hormones such as insulin and glucagon as well as ...
-
Cancerous tumours are voracious. Once they have consumed all the oxygen and nutrients in the original tumour site, the cancer cells travel t...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου