Background. There is a growing controversy about the use of oronasal masks (ONM) or total facemask (TFM) in noninvasive positive pressure ventilation (NPPV), so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods. Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t-test and chi-square test. Repeated measures ANOVA and Mann–Whitney U test were used to compare clinical and laboratory data. Results. There were no differences in venous blood gas (VBG) values between the two groups (). However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2) (). Patient comfort and acceptance were statistically similar in both groups (). Total time of NPPV was also similar in the two groups (). Conclusions. TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2k0ueRi
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2Gchesc via IFTTT
-
Abstract Determining the cause of unexplained death in all age groups, including infants, is a priority in forensic medicine. The triple r...
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2BeOBVJ via IFTTT
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2rxuJIO via IFTTT
-
Abstract In this paper we present the study of a skull belonging to a young male from the Italian Bronze Age showing three perimortem inju...
-
Abstract To measure integral doses in image-guided radiation therapy, we developed an integral condenser dosimeter comprising a disposable...
-
Objectives. To assess the association between short-term postoperative cognitive dysfuction (POCD) and inflammtory response in patients unde...
-
Abstract Layer-by-layer (LbL) dip coating, accompanying with the use of micelle structure, allows hydrophobic molecules to be coated on me...
-
This paper presents an adaptive multiuser transceiver scheme for DS-CDMA systems in which pilot symbols are added to users’ data to estimate...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου