This paper presents a DC side oriented diagnostic method for photovoltaic fields which operates on string currents previously supplied by an appropriate monitoring system. The relevance of the work relies on the definition of an effective and reliable day-by-day target for the power that every string of the field should have produced. The procedure is carried out by comparing the instantaneous power produced by all solar strings having the same orientation and by attributing, as producible power for all of them, the maximum value. As figure of merit, the difference between the maximum allowed energy production (evaluated as the integral of the power during a defined time interval) and the energy actually produced by the strings is defined. Such a definition accounts for both weather and irradiance conditions, without needing additional sensors. The reliability of the approach was experimentally verified by analyzing the performance of two medium size solar fields that were monitored over a period of four years. Results allowed quantifying energy losses attributable to underperforming solar strings and precisely locating their position in the field.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2iBFW7E
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2Gchesc via IFTTT
-
Abstract Determining the cause of unexplained death in all age groups, including infants, is a priority in forensic medicine. The triple r...
-
Abstract Layer-by-layer (LbL) dip coating, accompanying with the use of micelle structure, allows hydrophobic molecules to be coated on me...
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2rxuJIO via IFTTT
-
from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader https://ift.tt/2BeOBVJ via IFTTT
-
Abstract In this paper we present the study of a skull belonging to a young male from the Italian Bronze Age showing three perimortem inju...
-
Find out more about the wide range of A Levels and full time courses available at Longley Park Sixth Form College, the only independent Sixt...
-
Abstract To measure integral doses in image-guided radiation therapy, we developed an integral condenser dosimeter comprising a disposable...
-
Objectives. To assess the association between short-term postoperative cognitive dysfuction (POCD) and inflammtory response in patients unde...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου