Publication date: 20 March 2017
Source:Gene, Volume 605
Author(s): Hicham El Hadi, Imane Abdellaoui-Maane, Denise Kottwitz, Manal El Amrani, Nadia Bouchoutrouch, Zineb Qmichou, Mehdi Karkouri, Hicham ElAttar, Hassan Errihani, Pedro L Fernandez, Youssef Bakri, Hassan Sefrioui, Abdeladim Moumen
Accurate measurement of Human epidermal growth factor receptor (HER2) gene expression is central for breast or stomach cancer therapy orientation and prognosis. The current standards testing methods for HER2 expression are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH).In the current study, we explored the use of quantitative real time reverse transcription-PCR (RT-qPCR) as a potential method for the accurate relative quantification of the HER2 gene using formalin fixed paraffin embedded (FFPE) breast cancer biopsy samples. The main aim of the current study is to measure the level of concordance of RT-qPCR based quantification of HER2 overexpression with both IHC and FISH. Accordingly, an endogenous control gene (ECG) is required for this relative quantification and should ideally be expressed equivalently across tested samples. Stably expressed ECGs have been selected from a panel of seven genes using GenEx V6 software which is based on geNorm and NormFinder and statistical methods. Quantification of HER2 gene expression was performed by our RT-qPCR-based test and compared to the results obtained by both IHC and FISH methods.HER2 gene quantification using RT-qPCR test was normalized using the two ECGs (RPL30 and RPL37A) that were successfully identified and selected from a panel of seven genes as the most stable and reliable ECGs. We evaluated a total of 216 FFPE tissue samples from breast cancer patients. The results obtained with RT-qPCR in the current study were compared to both IHC and FISH data collected for the same patients. In addition to an internal evaluation, an external evaluation of this assay was also performed in a recognized pathology center in Europe (Clinic Barcelona Hospital Universitari, Spain) using 116 FFPE breast cancer tissue samples. The results demonstrated a high concordance between RT-qPCR and either IHC (98%) or FISH (72%) methods. Accordantly, the overall concordance was 85%.To our knowledge, this is the first study using the specific combination of RPL30 and RPL37 as reference genes for an accurate HER2 gene quantification in FFPE biopsy samples. Although further clinical validation regarding evolution and therapeutic response using RT-qPCR for the quantification of HER2 expression are still needed, the present study constitutes definitely a factual element that the RT-qPCR based assay may constitute a valid complementary test to accurately measure HER2 expression for a better treatment orientation.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2imvaQ5
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
UM-Chor1: establishment and characterization of the first validated clival chordoma cell line. J Neurosurg. 2017 Apr 21;:1-9 Authors:...
-
Publication date: Available online 10 May 2017 Source: Journal of Dairy Science Author(s): R.E. Vibart, M. Tavendale, D. Otter, B.H. Schw...
-
Competency-based psychiatric education for Indian medical undergraduates Vijayalakshmi Pernenkil Archives of Mental Health 2019 20(1):1-2 Be...
-
Related Articles Developmental control of macrophage function. Curr Opin Immunol. 2017 Dec 13;50:64-74 Authors: Bonnardel J, Guillia...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2tcPIjn via IFTTT
-
Abstract: Epidermolytic ichthyosis (EI) is a rare disorder of cornification caused by mutations in KRT1 and KRT10, encoding two suprabasal e...
-
Bloomberg Celgene Settles Whistle-Blower Fraud Suit for $280 Million Bloomberg Even after the FDA approved Thalomid for multiple myelo...
-
Related Articles Chinese version of the Constant-Murley questionnaire for shoulder pain and disability: a reliability and validation ...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου