Publication date: Available online 28 December 2016
Source:Brachytherapy
Author(s): Mark J. Rivard
PurposeA brachytherapy (BT) device has been developed with shielding to provide directional BT for preferentially irradiating malignancies while sparing healthy tissues. The CivaSheet is a flexible low-dose-rate BT device containing CivaDots with 103Pd shielded by a thin Au disk. This is the first report of a clinical dosimetric characterization of the CivaSheet device.Methods and MaterialsRadiation dose distributions near a CivaDot were estimated using the MCNP6 radiation transport code. CivaSheet arrays were also modeled to evaluate the dose superposition principle for treatment planning. The resultant data were commissioned in a treatment planning system (TPS) (VariSeed 9.0), and the accuracy of the dose superposition principle was evaluated for summing individual elements comprising a planar CivaSheet.ResultsThe dose-rate constant (0.579 cGy/h/U) was lower than for 103Pd seeds due to Au L-shell x-rays increasing the air-kerma strength. Radial dose function values at 0.1, 0.5, 2, 5, and 10 cm were 1.884, 1.344, 0.558, 0.088, and 0.0046, respectively. The two-dimensional anisotropy function exhibited dramatic reduction between the forward (0°) and rearward (180°) directions by a factor of 276 at r = 0.1 cm, 24 at r = 1 cm, and 5.3 at r = 10 cm. This effect diminished due to increasingly scattered radiation. The largest gradient in the two-dimensional anisotropy function was in contact with the device at 92° due to the Au disk shielding. TPS commissioning and dose superposition accuracies were typically within 2%.ConclusionsSimulations of the CivaDot yielded comprehensive dosimetry parameters that were entered into a TPS and deemed acceptable for clinical use. Dosimetry measurements of the CivaSheet are also of interest to the BT community.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2iH5kGs
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT