Publication date: May 2018
Source:European Journal of Radiology, Volume 102
Author(s): Usman Mahmood, Natally Horvat, Joao Vicente Horvat, Davinia Ryan, Yiming Gao, Gabriella Carollo, Rommel DeOcampo, Richard K. Do, Seth Katz, Scott Gerst, C. Ross Schmidtlein, Lawrence Dauer, Yusuf Erdi, Lorenzo Mannelli
PurposeClinical applications of dual energy computed tomography (DECT) have been widely reported; however, the importance of the different image reconstructions and radiation organ dose remains a relevant area of investigation, particularly considering the different commercially available DECT equipment. Therefore, the purpose of this study was to assess the image reliability and compare the information content between several image reconstructions in a rapid-switching DECT (rsDECT), and assess radiation organ dose between rsDECT and conventional single-energy computed tomography (SECT) exams.Materials and methodsThis Institutional Review Board-approved retrospective study included 98 consecutive patients who had a history of liver cancer and underwent multiphasic liver CT exams with rsDECT applied during the late arterial phase between June 2015 and December 2015. Virtual monochromatic 70 keV, material density images (MDI) iodine (-water) and virtual unenhanced (VUE) images were generated. Radiation dose analysis was performed in a subset of 44 patients who had also undergone a multiphasic SECT examination within 6 months of the rsDECT. Four board-certified abdominal radiologists reviewed 24–25 patients each, and a fifth radiologist re-evaluated all the scans to reach a consensus. The following imaging aspects were assessed by the radiologists: (a) attenuation measurements were made in the liver and spleen in VUE and true unenhanced (TUE) images; (b) subjective evaluation for lesion detection and conspicuity on MDI iodine (-water)/VUE images compared with the virtual monochromatic images/TUE images; and (c) overall image quality using a five-point Likert scale. The radiation dose analyses were evaluated in the subset of 44 patients regarding the following parameters: CTDIvol, dose length product, patient's effective diameter and organ dose using a Monte Carlo-based software, VirtualDose™ (Virtual Phantoms, Inc.) to 21 organs.ResultsOn average, image noise on the TUE images was 49% higher within the liver (p < 0.0001) and 48% higher within the spleen (p < 0.0001). CT numbers for the spleen were significantly higher on VUE images (p < 0.0001). Twenty-eight lesions in 24/98 (24.5%) patients were not observed on the VUE images. The conspicuity of vascular anatomy was considered better on MDI iodine (-water) Images 26.5% of patients. Using the Likert scale, the rsDECT image quality was considered to be satisfactory. Considering the subset of 44 patients with recent SECT, the organ dose was, on average, 37.4% less with rsDECT. As the patient's effective diameter decreased, the differences in dose between the rsDECT and SECT increased, with the total average organ dose being less by 65.1% when rsDECT was used.ConclusionVUE images in the population had lower image noise than TUE images; however, a few small and hyperdense findings were not characterized on VUE images. Delineation of vascular anatomy was considered better in around a quarter of patients on MDI iodine (-water) images. Finally, radiation dose, particularly organ dose, was found to be lower with rsDECT, especially in smaller patients.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2Dvx36K
Πέμπτη 15 Μαρτίου 2018
Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
2016-09-24T01-16-18Z Source: International Journal of Research in Medical Sciences Biswajit Majumder, Viral Tandel, Sandip Ghosh, Sharmis...
-
JPM, Vol. 8, Pages 5: Acknowledgement to Reviewers of Journal of Personalized Medicine in 2017 Journal of Personalized Medicine doi: 10.339...
-
Antibodies, Vol. 7, Pages 6: In-Depth Comparison of Lysine-Based Antibody-Drug Conjugates Prepared on Solid Support Versus in Solution Anti...
-
This paper proposes an enhanced ant colony optimization with dynamic mutation and ad hoc initialization, ACODM-I, for improving the accuracy...
-
No large-scale, head-to-head, phase III, randomized, controlled trial with an adequate sample size has investigated the effect of concurrent...
-
by Alison M. Hixon, Guixia Yu, J. Smith Leser, Shigeo Yagi, Penny Clarke, Charles Y. Chiu, Kenneth L. Tyler In 2014, the United States exp...
-
Accumulating data have indicated that citrus polymethoxyflavones (PMFs) have the ability to affect brain function. In the present study, we ...
-
ACS Nano DOI: 10.1021/acsnano.7b02426 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2h1neaG via...
-
Related Articles Long-acting insulin allergy in a diabetic child. Int J Immunopathol Pharmacol. 2017 Apr 01;:394632017700431 Authors...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου