Publication date: May–June 2018
Source:Reports of Practical Oncology & Radiotherapy, Volume 23, Issue 3
Author(s): Annamaria Didona, Valentina Lancellotta, Claudio Zucchetti, Bianca Moira Panizza, Alessandro Frattegiani, Martina Iacco, Anna Concetta Di Pilato, Simonetta Saldi, Cynthia Aristei
BackgroundIntensity-modulated radiotherapy (IMRT) improves dose distribution in head and neck (HN) radiation therapy. Volumetric-modulated arc therapy (VMAT), a new form of IMRT, delivers radiation in single or multiple arcs, varying dose rates (VDR-VMAT) and gantry speeds, has gained considerable attention. Constant dose rate VMAT (CDR-VMAT) associated with a fixed gantry speed does not require a dedicated linear accelerator like VDR-VMAT. The present study explored the feasibility, efficiency and delivery accuracy of CDR-VMAT, by comparing it with IMRT and VDR-VMAT in treatment planning for HN cancer.Methods and materialsStep and shoot IMRT (SS-IMRT), CDR-VMAT and VDR-VMAT plans were created for 15 HN cancer patients and were generated by Pinnacle3 TPS (v 9.8) using 6MV photon energy. Three PTVs were defined to receive respectively prescribed doses of 66Gy, 60Gy and 54Gy, in 30 fractions. Organs at risk (OARs) included the mandible, spinal cord, brain stem, parotids, salivary glands, esophagus, larynx and thyroid. SS-IMRT plans were based on 7 co-planar beams at fixed gantry angles. CDR-VMAT and VDR-VMAT plans, generated by the SmartArc module, used a 2-arc technique: one clockwise from 182° to 178° and the other one anti-clockwise from 178° to 182°. Comparison parameters included dose distribution to PTVs (Dmean, D2%, D50%, D95%, D98% and Homogeneity Index), maximum or mean doses to OARs, specific dose-volume data, the monitor units and treatment delivery times.ResultsCompared with SS-IMRT, CDR-VMAT significantly reduced the maximum doses to PTV1 and PTV2 and significantly improved all PTV3 parameters, except D98% and D95%. It significantly spared parotid and submandibular glands and was associated with a lower Dmean to the larynx. Compared with VDR-VMAT, CDR-VMAT was linked to a significantly better Dmean, to the PTV3 but results were worse for the parotids, left submandibular gland, esophagus and mandible. Furthermore, the Dmean to the larynx was also worse. Compared with SS-IMRT and VDR-VMAT, CDR-VMAT was associated with higher average monitor unit values and significantly shorter average delivery times.ConclusionsCDR-VMAT appeared to be a valid option in Radiation Therapy Centers that lack a dedicated linear accelerator for volumetric arc therapy with variable dose-rates and gantry velocities, and are unwilling or unable to sanction major expenditure at present but want to adopt volumetric techniques.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2FZxBUM
Τρίτη 20 Μαρτίου 2018
Is volumetric modulated arc therapy with constant dose rate a valid option in radiation therapy for head and neck cancer patients?
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Despite widespread journal endorsement of reporting guidelines, the poor reproducibility of preclinical research is increasingly under debat...
-
The benefit of the breastfeeding has been well-established. In comparison to partial breast feeding, exclusive breastfeeding has even more b...
-
A report of the Cold Spring Harbor Laboratory/Wellcome Trust Meeting on Engineering Principles in Biology, Cambridge, UK, 14-16 October 2009...
-
Abstract We report here a microscopic tight-binding theoretical study of the dynamic dielectric response of graphene-on-polarizable substr...
-
Volumetry measurement of lung nodules is gaining clinical acceptance but still... Read more on AuntMinnieEurope.com Related Reading: Ul...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου