Publication date: March–April 2018
Source:Reports of Practical Oncology & Radiotherapy, Volume 23, Issue 2
Author(s): K Mohamathu Rafic, S Amalan, B S Timothy Peace, B Paul Ravindran
Background and aimThe practicability of computing dose calculation on cone beam CT (CBCT) has been widely investigated. In most clinical scenarios, the craniocaudal scanning length of CBCT is found to be inadequate for localization. This study aims to explore extended tomographic localization and adaptive dose calculation strategies using Hounsfield unit (HU) corrected CBCT image sets.Materials and methodsPlanning CT (pCT) images of the Rando phantom (T12-to-midthigh) were acquired with pelvic-protocol using Biograph CT-scanner. Similarly, half-fan CBCT were acquired with fixed parameters using Clinac2100C/D linear accelerator integrated with an on-board imager with 2-longitudinal positions of the table. For extended localization and dose calculation, two stitching strategies viz., one with "penumbral-overlap" (S1) and the other with "no-overlap" (S2) and a local HU-correction technique were performed using custom-developed MATLAB scripts. Fluence modulated treatment plans computed on pCT were mapped with stitched CBCT and the dosimetric analyses such as dose-profile comparison, 3D-gamma (γ) evaluation and dose-volume histogram (DVH) comparison were performed.ResultsLocalizing scanning length of CBCT was extended by up to 15cm and 16cm in S1 and S2 strategies, respectively. Treatment plan mapping resulted in minor variations in the volumes of delineated structures and the beam centre co-ordinates. While the former showed maximum variations of −1.4% and −1.6%, the latter showed maximum of 1.4mm and 2.7mm differences in anteroposterior direction in S1 and S2 protocols, respectively. Dosimetric evaluations viz., dose profile and DVH comparisons were found to be in agreement with one another. In addition, γ-evaluation results showed superior pass-rates (≥98.5%) for both 3%/3mm dose-difference (DD) and distance-to-agreement (DTA) and 2%/2mm DD/DTA criteria with desirable dosimetric accuracy.ConclusionCone beam tomographic stitching and local HU-correction strategies developed to facilitate extended localization and dose calculation enables routine adaptive re-planning while circumventing the need for repeated pCT.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2FGONlR
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Liver ischemia reperfusion injury (IRI) is inevitable during transplantation and resection and is characterized by hepatocellular injury. Th...
-
Family: Know the drill New Straits Times Online One of my sons had this so often that his tonsils were removed. ... However, for som...
-
UM-Chor1: establishment and characterization of the first validated clival chordoma cell line. J Neurosurg. 2017 Apr 21;:1-9 Authors:...
-
Publication date: Available online 10 May 2017 Source: Journal of Dairy Science Author(s): R.E. Vibart, M. Tavendale, D. Otter, B.H. Schw...
-
P Chaitanya, D Praveen, Madhusudhan Reddy Indian Dermatology Online Journal 2017 8(3):205-207 Mucocele is a common salivary gland disord...
-
Abstract Background Cancer patients suffer in part because some health professionals prescribe or administer amounts of analgesics, namely...
-
Publication date: Available online 2 November 2017 Source: Journal of Dairy Science Author(s): R.C. Neves, B.M. Leno, M.D. Curler, M.J. T...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου