Publication date: March–April 2018
Source:Reports of Practical Oncology & Radiotherapy, Volume 23, Issue 2
Author(s): K Mohamathu Rafic, S Amalan, B S Timothy Peace, B Paul Ravindran
Background and aimThe practicability of computing dose calculation on cone beam CT (CBCT) has been widely investigated. In most clinical scenarios, the craniocaudal scanning length of CBCT is found to be inadequate for localization. This study aims to explore extended tomographic localization and adaptive dose calculation strategies using Hounsfield unit (HU) corrected CBCT image sets.Materials and methodsPlanning CT (pCT) images of the Rando phantom (T12-to-midthigh) were acquired with pelvic-protocol using Biograph CT-scanner. Similarly, half-fan CBCT were acquired with fixed parameters using Clinac2100C/D linear accelerator integrated with an on-board imager with 2-longitudinal positions of the table. For extended localization and dose calculation, two stitching strategies viz., one with "penumbral-overlap" (S1) and the other with "no-overlap" (S2) and a local HU-correction technique were performed using custom-developed MATLAB scripts. Fluence modulated treatment plans computed on pCT were mapped with stitched CBCT and the dosimetric analyses such as dose-profile comparison, 3D-gamma (γ) evaluation and dose-volume histogram (DVH) comparison were performed.ResultsLocalizing scanning length of CBCT was extended by up to 15cm and 16cm in S1 and S2 strategies, respectively. Treatment plan mapping resulted in minor variations in the volumes of delineated structures and the beam centre co-ordinates. While the former showed maximum variations of −1.4% and −1.6%, the latter showed maximum of 1.4mm and 2.7mm differences in anteroposterior direction in S1 and S2 protocols, respectively. Dosimetric evaluations viz., dose profile and DVH comparisons were found to be in agreement with one another. In addition, γ-evaluation results showed superior pass-rates (≥98.5%) for both 3%/3mm dose-difference (DD) and distance-to-agreement (DTA) and 2%/2mm DD/DTA criteria with desirable dosimetric accuracy.ConclusionCone beam tomographic stitching and local HU-correction strategies developed to facilitate extended localization and dose calculation enables routine adaptive re-planning while circumventing the need for repeated pCT.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2FGONlR
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Abstract Over the past decades, an increasing need in renewable resources has progressively appeared. This trend concerns not only fossil f...
-
Zeinab Nazeeh Shata, Marwa R Amin, Heba M El-Kady, Mervat W Abu-Nazel Avicenna Journal of Medicine 2017 7(2):54-63 Background: Unlike ot...
-
Brain Networks are Independently Modulated by Donepezil, Sleep, and Sleep Deprivation. Brain Topogr. 2017 Nov 23;: Authors: Wirsich J...
-
Abstract Diphenylarsinic acid (DPAA) is an organic arsenic compound used for the synthesis of chemical weapons. We previously found that th...
-
Vol.10 No.8 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/22FyVm0 via IFTTT
-
Whether to wear a pollution filter Development of air quality forecasting system in Macedonia, based on WRF-Chem model Abstract Urban air qu...
-
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2hMrBnH
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου