Παρασκευή 16 Μαρτίου 2018

Extended localization and adaptive dose calculation using HU corrected cone beam CT: Phantom study

elsevier-non-solus.png

Publication date: March–April 2018
Source:Reports of Practical Oncology & Radiotherapy, Volume 23, Issue 2
Author(s): K Mohamathu Rafic, S Amalan, B S Timothy Peace, B Paul Ravindran
Background and aimThe practicability of computing dose calculation on cone beam CT (CBCT) has been widely investigated. In most clinical scenarios, the craniocaudal scanning length of CBCT is found to be inadequate for localization. This study aims to explore extended tomographic localization and adaptive dose calculation strategies using Hounsfield unit (HU) corrected CBCT image sets.Materials and methodsPlanning CT (pCT) images of the Rando phantom (T12-to-midthigh) were acquired with pelvic-protocol using Biograph CT-scanner. Similarly, half-fan CBCT were acquired with fixed parameters using Clinac2100C/D linear accelerator integrated with an on-board imager with 2-longitudinal positions of the table. For extended localization and dose calculation, two stitching strategies viz., one with "penumbral-overlap" (S1) and the other with "no-overlap" (S2) and a local HU-correction technique were performed using custom-developed MATLAB scripts. Fluence modulated treatment plans computed on pCT were mapped with stitched CBCT and the dosimetric analyses such as dose-profile comparison, 3D-gamma (γ) evaluation and dose-volume histogram (DVH) comparison were performed.ResultsLocalizing scanning length of CBCT was extended by up to 15cm and 16cm in S1 and S2 strategies, respectively. Treatment plan mapping resulted in minor variations in the volumes of delineated structures and the beam centre co-ordinates. While the former showed maximum variations of −1.4% and −1.6%, the latter showed maximum of 1.4mm and 2.7mm differences in anteroposterior direction in S1 and S2 protocols, respectively. Dosimetric evaluations viz., dose profile and DVH comparisons were found to be in agreement with one another. In addition, γ-evaluation results showed superior pass-rates (≥98.5%) for both 3%/3mm dose-difference (DD) and distance-to-agreement (DTA) and 2%/2mm DD/DTA criteria with desirable dosimetric accuracy.ConclusionCone beam tomographic stitching and local HU-correction strategies developed to facilitate extended localization and dose calculation enables routine adaptive re-planning while circumventing the need for repeated pCT.



from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2FGONlR

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Δημοφιλείς αναρτήσεις