Objectives The aim of this study was to compare computer-aided diagnosis (CAD) and visual reading for the detection of subsolid nodules (SSNs) in volumetrl measuremic low-dose computed tomography (LDCT) for lung cancer screening. Materials and Methods Prospective visual detection (VD) and manuaent of SSN were performed in the 2303 baseline volumetric LDCTs of the Multicenter Italian Lung Detection trial. Baseline and 2- and 4-year LDCTs underwent retrospective CAD analysis, subsequently reviewed by 2 experienced thoracic radiologists. The reference standard was defined by the cumulative number of SSNs detected by any reading method between VD and CAD. The number of false-positive CAD marks per scan (FPSSN/scan) was calculated. The positive predictive value of CAD was quantified per nodule (PPVSSN) and per screenee (PPVScreenee). The sensitivity and negative predictive value were compared between CAD and VD. The longitudinal 3-time-point sensitivity of CAD was calculated in the subgroup of persistent SSNs seen by VD (ratio between the prevalent SSNs detected by CAD through 3 time points and the total number of persistent prevalent SSNs detected by VD) to test the sensitivity of iterated CAD analysis during a screening program. Semiautomatic characteristics (diameter, volume, and mass; both for whole nodule and solid component) were compared between SSN detected CAD-only or VD-only to investigate whether either reading method could suffer from specific sensitivity weakness related to SSN features. Semiautomatic and manual diameters were compared using Spearman ρ correlation and Bland-Altman plot. Results Computer-aided diagnosis and VD detected a total of 194 SSNs in 6.7% (155/2,303) of screenees at baseline LDCT. The CAD showed mean FPSSN/scan of 0.26 (604/2,303); PPVSSN 22.5% (175/779) for any SSN, with 54.4% (37/68) for PSN and 19.4% for NSN (138/711; P
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2IrnXvq
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jHOyKt via IFTTT
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2Fl3FVV via IFTTT
-
Abstract Bone homeostasis is maintained by a balance between resorption of the bone matrix and its replacement by new bone. Osteoclasts p...
-
Abstract Continuous tooth replacement is common for tetrapods, but some groups of acrodont lepidosaurs have lost the ability to replace th...
-
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2God5y1
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου