Objectives The aim of this study was to investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine and fat quantification in differentiating adrenal gland adenomas from metastases. Materials and Methods Sixty-two patients (38 men and 24 women; mean age, 69.1 years) underwent clinically indicated DECT of the abdomen on a third-generation dual-source scanner. Examinations were retrospectively included due to detected adrenal masses. For each adrenal lesion, unenhanced and contrast-enhanced attenuation values, as well as dual-energy iodine density and fat fraction, were recorded. Additional magnetic resonance imaging data, positron emission tomography/computed tomography scans, interval imaging follow-up, and histopathological analysis were used as the reference standard for all adrenal lesions. Mean values of unenhanced and contrast-enhanced attenuation, as well as material densities, were compared between adenomas, metastases, and normal adrenal glands. Furthermore, the diagnostic accuracy of unenhanced, contrast-enhanced, and material density analysis was assessed between adrenal adenomas and metastases. Results Adrenal adenomas showed significant differences regarding iodine density and fat fraction values (1.3 ± 0.4 mg/mL and 34.2% ± 12.6%) in comparison with adrenal metastases (3.2 ± 1.4 mg/mL and 10.7% ± 7.8%) and normal adrenal glands (1.7 ± 0.6 mg/mL and 18.7% ± 12.0%) (all P ≤ 0.004). Analysis of unenhanced attenuation values revealed no significant differences between healthy adrenal parenchyma (19.1 ± 15.6 HU) and adrenal metastases (26.9 ± 16.2 HU) (P = 0.135). Iodine density and fat fraction analysis showed significantly higher diagnostic accuracy for the diagnosis of adenomas (sensitivity, 97% and 89%; specificity, 96% and 89%, respectively) compared with unenhanced and contrast-enhanced evaluation (sensitivity, 65% and 58%; specificity, 73% and 85%, respectively) (P ≤ 0.023). The combined diagnostic value of iodine density and fat fraction analysis revealed a sensitivity of 97% and a specificity of 100%. Conclusions Third-generation dual-source DECT iodine and fat quantification allow for differentiation between adrenal adenomas and metastases with high diagnostic accuracy.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2E6mmsx
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου