Rationale and ObjectivesThis study aims to determine the optimal photon energy for image quality of the pulmonary arteries (PAs) on dual-energy computed tomography (CT) pulmonary angiography (CTPA) utilizing low volumes of iodinated contrast.Materials and MethodsThe study received institutional review board exemption and was Health Insurance Portability and Accountability Act compliant. Adults (n = 56) who underwent dual-energy CTPA with 50–60 cc of iodinated contrast on a third-generation dual-source multidetector CT were retrospectively and consecutively identified. Twelve virtual monoenergetic kiloelectron volt (keV) image data sets (40–150 keV, 10-keV increments) were generated with a second-generation noise-reducing algorithm. Standard regions of interest were placed on main, right, left, and right interlobar pulmonary arteries; pectoralis muscle; and extrathoracic air. Attenuation [mean CT number (Hounsfield unit, HU)], noise [standard deviation (HU)], signal to noise (SNR), and contrast to noise ratio were evaluated. Three blinded chest radiologists rated (from 1 to 5, with 5 being the best) randomized monoenergetic and weighted-average images for attenuation and noise. P < .05 was considered significant.ResultsRegion of interest mean CT number increased as keV decreased, with 40 keV having the highest value (P < .001). Mean SNR was highest for 40–60 keV (P < .05) (14.5–14.7) and was higher (P < .05) than all remaining energies (90–150 keV) for all vessel regions combined. Contrast to noise ratio was highest for 40 keV (P < .001) and decreased as keV increased. SNR was highest at 60 and 70 keV, only slightly higher than 40–50 keV (P < .05). Reader scores for 40–50 keV were greater than other energies and weighted-average images (P < .05).ConclusionsKiloelectron volt images of 40–50 keV from the second-generation algorithm optimize attenuation on dual-energy CTPA and can potentially aid in interpretation and avoiding nondiagnostic examinations.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2EHk1rF
Παρασκευή 16 Φεβρουαρίου 2018
Image Quality on Dual-energy CTPA Virtual Monoenergetic Images
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
New analysis shows that some of these amazing flying beasts were far more formidable than we'd ever thought before... -- Read more on...
-
Do you speak NHS?Oh, yes: you don’t get far in the health service without being able to generate a seamless flow of the right words, if only...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oDLxf6 via IFTTT
-
The government has announced its intention to make sex and relationships education (SRE) statutory in all secondary schools, and to make rel...
-
Abstract Purpose The aim of this study is to evaluate the feasibility of a telehealthcare application for operable lung cancer (OLC) patie...
-
Bristol-Myers Squibb Co Cancer Drug Cost Comes Under Fire In U.K. StockNews.com (blog) NICE noted the evidence that nivolumab can ext...
-
Abstract Background Medical therapy efficacy remains controversial in stricturing Crohn's disease. Cross-sectional imaging, especial...
-
Abstract The applicability of comprehensive two-dimensional gas chromatography (GC×GC) using a single-stage thermal modulator was explored...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2o3hqws via IFTTT
-
Abstract Patients with sulfite oxidase (SO) deficiency present severe brain abnormalities, whose pathophysiology is not yet elucidated. We...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου