Rationale and ObjectivesThis study aims to determine the optimal photon energy for image quality of the pulmonary arteries (PAs) on dual-energy computed tomography (CT) pulmonary angiography (CTPA) utilizing low volumes of iodinated contrast.Materials and MethodsThe study received institutional review board exemption and was Health Insurance Portability and Accountability Act compliant. Adults (n = 56) who underwent dual-energy CTPA with 50–60 cc of iodinated contrast on a third-generation dual-source multidetector CT were retrospectively and consecutively identified. Twelve virtual monoenergetic kiloelectron volt (keV) image data sets (40–150 keV, 10-keV increments) were generated with a second-generation noise-reducing algorithm. Standard regions of interest were placed on main, right, left, and right interlobar pulmonary arteries; pectoralis muscle; and extrathoracic air. Attenuation [mean CT number (Hounsfield unit, HU)], noise [standard deviation (HU)], signal to noise (SNR), and contrast to noise ratio were evaluated. Three blinded chest radiologists rated (from 1 to 5, with 5 being the best) randomized monoenergetic and weighted-average images for attenuation and noise. P < .05 was considered significant.ResultsRegion of interest mean CT number increased as keV decreased, with 40 keV having the highest value (P < .001). Mean SNR was highest for 40–60 keV (P < .05) (14.5–14.7) and was higher (P < .05) than all remaining energies (90–150 keV) for all vessel regions combined. Contrast to noise ratio was highest for 40 keV (P < .001) and decreased as keV increased. SNR was highest at 60 and 70 keV, only slightly higher than 40–50 keV (P < .05). Reader scores for 40–50 keV were greater than other energies and weighted-average images (P < .05).ConclusionsKiloelectron volt images of 40–50 keV from the second-generation algorithm optimize attenuation on dual-energy CTPA and can potentially aid in interpretation and avoiding nondiagnostic examinations.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2EHk1rF
Παρασκευή 16 Φεβρουαρίου 2018
Image Quality on Dual-energy CTPA Virtual Monoenergetic Images
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Despite widespread journal endorsement of reporting guidelines, the poor reproducibility of preclinical research is increasingly under debat...
-
The benefit of the breastfeeding has been well-established. In comparison to partial breast feeding, exclusive breastfeeding has even more b...
-
A report of the Cold Spring Harbor Laboratory/Wellcome Trust Meeting on Engineering Principles in Biology, Cambridge, UK, 14-16 October 2009...
-
Abstract We report here a microscopic tight-binding theoretical study of the dynamic dielectric response of graphene-on-polarizable substr...
-
Volumetry measurement of lung nodules is gaining clinical acceptance but still... Read more on AuntMinnieEurope.com Related Reading: Ul...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου