Publication date: Available online 15 February 2018
Source:Academic Radiology
Author(s): Bari Dane, Hersh Patel, Thomas O'Donnell, Francis Girvin, Geraldine Brusca-Augello, Jeffrey B. Alpert, Bowen Niu, Mariam Attia, James Babb, Jane P. Ko
Rationale and ObjectivesThis study aims to determine the optimal photon energy for image quality of the pulmonary arteries (PAs) on dual-energy computed tomography (CT) pulmonary angiography (CTPA) utilizing low volumes of iodinated contrast.Materials and MethodsThe study received institutional review board exemption and was Health Insurance Portability and Accountability Act compliant. Adults (n = 56) who underwent dual-energy CTPA with 50–60 cc of iodinated contrast on a third-generation dual-source multidetector CT were retrospectively and consecutively identified. Twelve virtual monoenergetic kiloelectron volt (keV) image data sets (40–150 keV, 10-keV increments) were generated with a second-generation noise-reducing algorithm. Standard regions of interest were placed on main, right, left, and right interlobar pulmonary arteries; pectoralis muscle; and extrathoracic air. Attenuation [mean CT number (Hounsfield unit, HU)], noise [standard deviation (HU)], signal to noise (SNR), and contrast to noise ratio were evaluated. Three blinded chest radiologists rated (from 1 to 5, with 5 being the best) randomized monoenergetic and weighted-average images for attenuation and noise. P < .05 was considered significant.ResultsRegion of interest mean CT number increased as keV decreased, with 40 keV having the highest value (P < .001). Mean SNR was highest for 40–60 keV (P < .05) (14.5–14.7) and was higher (P < .05) than all remaining energies (90–150 keV) for all vessel regions combined. Contrast to noise ratio was highest for 40 keV (P < .001) and decreased as keV increased. SNR was highest at 60 and 70 keV, only slightly higher than 40–50 keV (P < .05). Reader scores for 40–50 keV were greater than other energies and weighted-average images (P < .05).ConclusionsKiloelectron volt images of 40–50 keV from the second-generation algorithm optimize attenuation on dual-energy CTPA and can potentially aid in interpretation and avoiding nondiagnostic examinations.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2EHk1rF
Παρασκευή 16 Φεβρουαρίου 2018
Image Quality on Dual-energy CTPA Virtual Monoenergetic Images
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Excerpt from Common Culture: Reading and Writing About American Popular Culture. Ed. Michael Petracca, Madeleine Sorapure. Upper Saddle Rive...
-
Thesis Statement Creator: Directions: This web page explains the different parts to a thesis statement and helps you create your own. You ca...
-
Effect of titanium oxide and zirconium oxide nanoparticle incorporation on the flexural strength of heat-activated polymethyl methacrylate d...
-
Publication date: Available online 20 March 2018 Source: Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology Author(s): Tobia...
-
Abstract Objectives Patients undergoing osteoporosis treatment benefit greatly from early detection. We previously developed a computer-...
-
Related Articles Return of Genetic Research Results to Participants and Families: IRB Perspectives and Roles. J Law Med Ethics. 2015;...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου