Publication date: Available online 4 January 2018
Source:European Journal of Radiology
Author(s): Eun Jung Choi, HyeMi Choi, Eun Hae Park, Ji Soo Song, Ji Hyun Youk
ObjectivesTo investigate the automated breast volume scanner (ABVS) in comparison with hand-held ultrasound (HHUS) according to the fifth edition of BI-RADS ultrasound.Material and MethodsA total of 831 lesions in 786 patients who underwent both HHUS and ABVS were included. Three radiologists independently evaluated the sonographic features of each lesion according to the fifth BI-RADS edition. The kappa coefficient (κ) was calculated for each BI-RADS descriptor and final assessment category. The accuracy of malignancy prediction and diagnostic performance of the BI-RADS descriptors were assessed using multivariate logistic regression and area under the receiver operator characteristic curve (AUC), respectively.ResultsABVS and HHUS showed moderate to good interobserver agreement (κ=0.53-0.67 and 0.55-0.70, respectively) except in associated features (κ=0.31 and 0.36, respectively) for BI-RADS lexicons. Irregular shape, a non-circumscribed margin, and posterior features (combined or shadowing) were independently associated with malignancy in both ABVS and HHUS. Calcification presence on ABVS (odds ratio [OR], 95% confidence interval [CI]: 2.09, 1.11–3.94) and non-parallel orientation on HHUS (OR, 95% CI: 2.04, 1.10–3.78) were independently associated with malignancy. There were no significant differences between ABVS and HHUS in sensitivity (84.2% vs. 84.2%), specificity (80.5% vs. 83.9%), or AUC (0.88 vs. 0.90).ConclusionsAccording to the fifth BI-RADS edition, ABVS is not statistically significantly different from HHUS with regard to interobserver variability and diagnostic performance.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2CIjLZn
Πέμπτη 4 Ιανουαρίου 2018
Evaluation of an automated breast volume scanner according to the fifth edition of BI-RADS for breast ultrasound compared with hand-held ultrasound
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου