Author(s): Shingo Ohira, Tsukasa Karino, Yoshihiro Ueda, Yuya Nitta, Naoyuki Kanayama, Masayoshi Miyazaki, Masahiko Koizumi, Teruki Teshima
Rationale and ObjectivesBecause it is imperative for understanding the performance of dual-energy computed tomography scanner to determine clinical diagnosis, we aimed to assess the accuracy of quantitative measurements using dual-energy computed tomography with fast kilovoltage switching.Materials and MethodsQuantitative measurements were performed for 16 reference materials (physical density, 0.965–1.550 g/cm3; diameter of rod, 2.0–28.5 mm; iodine concentration, 2–15 mg/mL; and calcium concentration, 50–300 mg/mL) with varying scanning settings, and the measured values were compared to their theoretical values.ResultsFor high-density material, the maximum differences in Hounsfield unit values in the virtual monochromatic images at 50, 70, and 100 keV were −176.2, 61.0, and −35.2 HU, respectively, and the standard deviations over short- and long-term periods were 11.1, 6.1, and 3.5 HU at maximum. The accuracy of the Hounsfield unit measurement at 50 and 70 keV was significantly higher (P < 0.05) with higher radiation output and smaller phantom size. The difference in the iodine and calcium measurements in the large phantom were up to −2.6 and −60.4 mg/mL for iodine (5 mg/mL with 2-mm diameter) and calcium (300 mg/mL) materials, and the difference was improved with a small phantom. Metal artifact reduction software improved subjective image quality; however, the quantitative values were significantly underestimated (P < 0.05) (−49.5, −26.9, and −15.3 HU for 50, 70, and 100 keV, respectively; −1.0 and −17 mg/mL for iodine and calcium concentration, respectively) compared to that acquired without a metal material.ConclusionsThe accuracy of quantitative measurements can be affected by material density and the size of the object, radiation output, phantom size, and the presence of metal materials.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2kD1UaR
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου