To achieve fast calibration of line structured light sensor, a geometric calibration approach based on single circular calibration target is proposed. The proposed method uses the circular points to establish linear equations, and according to the angle constraint, the camera intrinsic parameters can be calculated through optimization. Then, the light plane calibration is accomplished in two steps. Firstly, when the vanishing lines of target plane at various postures are obtained, the intersections between vanishing lines and laser stripe can be computed, and the normal vector of light plane can be calibrated via line fitting method using intersection points. After that, the distance from the origin of camera coordinate system to the light plane can be derived based on the model of perspective-three-point. The actual experimental result shows that this calibration method has high accuracy, its average measuring accuracy is 0.0451 mm, and relative error is 0.2314%. In addition, the entire calibration process has no complex operations. It is simple, convenient, and suitable for calibration on sites.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2DDyErO
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
ACS Nano DOI: 10.1021/acsnano.7b04100 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2h0ZFyU via...
-
Molecules, Vol. 24, Pages 2837: Bioavailability and Bioactivity of Encapsulated Phenolics and Carotenoids Isolated from Red Pepper Waste Mol...
-
Whether to wear a pollution filter Development of air quality forecasting system in Macedonia, based on WRF-Chem model Abstract Urban air qu...
-
Abstract Background Henoch–Schönlein purpura is the most common vasculitis in children. Its long-term prognosis depends on renal involve...
-
Denotation as Complex and Chronologically Extended: anvitābhidhāna in Śālikanātha's Vākyārthamātṛkā - I Abstract The two theories of ve...
-
UM-Chor1: establishment and characterization of the first validated clival chordoma cell line. J Neurosurg. 2017 Apr 21;:1-9 Authors:...
-
Publication date: Available online 10 May 2017 Source: Journal of Dairy Science Author(s): R.E. Vibart, M. Tavendale, D. Otter, B.H. Schw...
-
Abstract Zinc finger protein 703 (ZNF703) is a putative oncogene in patients with the luminal B molecular subtype of breast cancer. Althou...
-
Abstract Cerebral and systemic organ microvascular pathologies coexist with human Alzheimer’s disease (AD) neuropathology. In this study, w...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου