Objective There has been controversy as to whether gadobutrol, one of the widely used macrocyclic gadolinium-based contrast agents, can lead to gadolinium retention after serial injections. Our aim was to validate whether serial administrations of gadobutrol can cause signal increase in the dentate nucleus (DN) and globus pallidus (GP) on unenhanced T1-weighted magnetic resonance (MR) images due to gadolinium retention. Materials and Methods A total of 189 patients who had undergone at least 2 contrast-enhanced MR scans using only gadobutrol between August 2009 and August 2016 were retrospectively included. The DN–to–pons and GP-to-thalamus signal intensity (SI) ratio differences on unenhanced T1-weighted MR images were calculated by subtracting the SI ratios at the first MR images from those at the last MR images. One-sample t tests were used to evaluate whether the SI ratio differences differed from 0. Linear regression and Pearson correlations were performed to assess correlations between SI ratio differences and various confounding variables, including the number of MR scans, mean time interval between MR scans, age, sex, history of radiation therapy or chemotherapy, and renal and liver functions. Results Patients underwent a mean of 5.9 ± 6.3 contrast-enhanced MR scans with a mean interval of 42.8 ± 49.5 weeks between the scans. Sixty-three patients underwent 6 or more MR scans, whereas 126 patients underwent fewer than 6 MR scans. Neither the DN-to-pons SI nor the GP-to-thalamus SI ratio differences differed significantly from 0, with mean values of −0.012 ± 0.115 (P = 0.148) and 0.012 ± 0.111 (P = 0.126), respectively. Conclusions Serial administrations of gadobutrol did not result in signal increases in the DN or GP on unenhanced T1-weighted MR images due to gadolinium retention.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2ka20FQ
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου