The effects of the wind/PV grid-connected system (GCS) can be categorized as technical, environmental, and economic impacts. It has a vital impact for improving the voltage in the power systems; however, it has some negative effects such as interfacing and fault clearing. This paper discusses different grounding methods for fault protection of High-voltage (HV) power systems. Influences of these grounding methods for various fault characteristics on wind/PV GCSs are discussed. Simulation models are implemented in the Alternative Transient Program (ATP) version of the Electromagnetic Transient Program (EMTP). The models allow for different fault factors and grounding methods. Results are obtained to evaluate the impact of each grounding method on the 3-phase short-circuit fault (SCF), double-line-to-ground (DLG) fault, and single-line-to-ground (SLG) fault features. Solid, resistance, and Petersen coil grounding are compared for different faults on wind/PV GCSs. Transient overcurrent and overvoltage waveforms are used to describe the fault case. This paper is intended as a guide to engineers in selecting adequate grounding and ground fault protection schemes for HV, for evaluating existing wind/PV GCSs to minimize the damage of the system components from faults. This research presents the contribution of wind/PV generators and their comparison with the conventional system alone.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2hLyMjK
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that pub...
-
You could soon get an even more immersive VR experience thanks to the Ambiotherm plug in, which exposes you to the elements of your virtual...
-
Abstract T cell immunoglobulin and mucin domain 3 (Tim-3) is a critical regulatory molecule found on activated Th1 cells, exhausted CD8 + ...
-
Join in on the conversation about GCSE Statistics Coursework Help on the TSR community forums. from #AlexandrosSfakianakis via Alexandros ...
-
CFS, also known as ME, may be caused by the body switching from fully breaking down carbohydrates to using other energy sources, bringing o...
-
Study of Sharp Corner Cutting In Wire EDM Thesis submitted in accordance with The test specimens have been cut by using different wire-cut E...
-
Visit this site dedicated to Valentine from 100 Valentine Poems for your special person. Famous Valentine Poems from the Worlds greatest Poe...
-
Planta Med DOI: 10.1055/s-0043-106050 Glucose homeostasis is maintained by antagonistic hormones such as insulin and glucagon as well as ...
-
Cancerous tumours are voracious. Once they have consumed all the oxygen and nutrients in the original tumour site, the cancer cells travel t...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου