Sameer K Taywade, Nishikant A Damle, Abhishek Behera, K Devasenathipathy, Chandrasekhar Bal, Madhavi Tripathi, Shipra Agarwal, Nikhil Tandon, Sunil Chumber, V Seenu
Indian Journal of Endocrinology and Metabolism 2017 21(3):399-403
Objective: We aimed to compare the diagnostic accuracy of 18F-Fluorocholine (FCH)-positron emission tomography/computed tomography (PET/CT) and four-dimensional (4D)- CT in detection and localization of eutopic and ectopic parathyroid adenoma (PA) in patients with hyperparathyroidism. Materials and Methods: Five patients with primary hyperparathyroidism underwent FCH-PET/CT after 60 min of 185 MBq of intravenous 18F-FCH administration. Images were acquired from head to mediastinum at 3 min per bed position. No intravenous contrast was used. All patients underwent 4D-CT within 2 weeks of the FCH-PET/CT, with a precontrast, post contrast arterial, and venous phase with 75 ml intravenous Iohexol 350 followed by 25 ml saline chase. Histopathology was considered as the gold standard. Results: Both modalities showed 100% concordance in the detection of parathyroid lesions. Both FCH-PET/CT and 4D-CT detected 7 lesions in 5 patients, with 4 patients having a single lesion, and 1 patient having three lesions. Of the 7 reported lesions, 4 were eutopic and 3 were ectopic. No additional lesions were detected by either modality in comparison to the other. All 7 specimens were resected and histopathology showed PA/hyperplasia. Conclusion: FCH-PET/CT and 4D-CT are equally efficacious in detection and localization of eutopic and ectopic PA. This may open up the possibility of using FCH-PET/CT in patients with negative conventional imaging who cannot undergo contrast studies.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2pufws6
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
-
Liver ischemia reperfusion injury (IRI) is inevitable during transplantation and resection and is characterized by hepatocellular injury. Th...
-
Accuracy of the Compressed Sensing Accelerated 3D-FLAIR Sequence for the Detection of MS Plaques at 3T. AJNR Am J Neuroradiol. 2...
-
Radioterapia oncologica, la Cattolica protagonista al Congresso Europeo insalutenews ... l'utilizzo della radioterapia stereotass...
-
Abstract Background Individualized medication reviews may improve our understanding of the distribution of CYP2C19 polymorphisms in ethn...
-
Abstract Biodegradable polymer blends of high-molecular-weight poly(3-hydroxybutyrate) (PHB) and poly(lactic acid) (PLA) are not miscible ...
-
Abstract Background Gastroparesis (GP)-like syndrome presents with the symptoms of GP but without delayed gastric emptying (GE). Whether...
-
Abstract Ethylene-octene copolymer (EOC)/organoclay nanocomposite was cured by peroxide in an internal mixer for different time periods. L...
-
Aim: This study was designed to evaluate the clinical characteristics and prognosis of elderly small cell lung cancer (SCLC) patients compli...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου