This paper examines the correlation of vibration properties and crack index of tunnel lining in evaluating risk of collapsing. The visual inspection method, which was widely used, was not reliable enough as the stability of tunnel lining was influenced by the voids and the cracks that were invisible. A new method for the health assessment of tunnel lining was proposed, which can evaluate the whole structural condition according to the vibration properties of tunnel lining. A series of field tests were conducted to evaluate the validity of this new method and to make a comparative analysis with the visual inspection test results. The resultant average spectrum (RAS) of tunnel lining was identified according to the acceleration data of ambient vibration test of Hidake Tunnel in Japan. The tunnel lining crack index (TCI) was also obtained by digital visual inspection test. The correlation between the vibration characteristics and the crack index of tunnel lining was confirmed. However, the voids and the cracks on the inside of the lining were neglected in visual inspection test, which could pose a serious threat to tunnel safety. The vibration measurements by seismometer are an effective way to evaluate the global stability of tunnel lining.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oo4dhb
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Objective Outpatient parenteral antimicrobial therapy (OPAT) provides opportunities for improved cost savings, but in the UK, implementation...
-
Abstract Purpose Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated informatio...
-
Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the resu...
-
Geographic region: Does it matter in cutaneous melanoma of the head and neck? Laryngoscope. 2017 Jun 05;: Authors: Kılıç S, Unsal AA,...
-
The overall objective of the guideline is to provide up-to-date, evidence-based recommendations for the management of lichen sclerosus (LS)...
-
Abstract The head-mounted display (HMD) has the potential to improve the quality of ultrasound-guided procedures. The aim of this non-clin...
-
http://ift.tt/2pnwWaQ
-
Objective. We compared the effects of transcranial direct current stimulation at different cortical sites (premotor and motor primary cortex...
-
Background. Globally 3 to 8% of reproductive age women are suffering from premenstrual dysphoric disorder (PMDD). Several mental and reprodu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου