In this work an overview of numerous possible processing modes in future dual frequency, dual constellation GBAS is given and compared to the current GAST D standard. We discuss the individual error contributions to GBAS protection levels and give an overview of the general processing. Based on this the consequences when adding a second constellation as well as frequency are investigated. Geometrical implications and changes to the residual differential error bounds are studied separately first. In terms of geometry a comparison between the single and dual constellation case is presented using dilution of precision as metric. The influence on the different sigma contributions when using new satellites (Galileo) and signals (E1, L5, and E5a) is individually discussed based on recent measurements. Final simulations for different varying parameters are carried out to compare relevant processing modes in terms of achieved nominal protection levels. A concluding discussion compares the outcomes and analyzes the implications of choosing one or the other mode.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/292sZzM
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Butyric Acid from Probiotic Staphyloco...
-
Medicine by Alexandros G. Sfakianakis,Αλέξανδρος Γ. Σφακιανάκης A Novel Technique for Endoscopic Repair of Large Anterior Skull Base Defect...
-
2016-11-22T07-55-59Z Source: International Journal of Medical Science and Public Health Banothu Srinivas, Madhu Mohan Reddy B. Backgrou...
-
2016-10-15T06-30-01Z Source: The Southeast Asian Journal of Case Report and Review Sangita Deepak Kamath, Neeraj Jain, Saurabh Pathak, Ba...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Abstract The development of focused ion beam-scanning electron microscopy (FIB-SEM) techniques has allowed high-resolution 3D imaging of n...
-
Vol.48 No.2 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1S2Z7n2 via IFTTT
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου