Warning beacons are critical for the safety of transportation, construction, and utility workers. These devices need to produce sufficient luminous intensity to be visible without creating glare to drivers. Published standards for the photometric performance of warning beacons do not address their performance in conditions of reduced visibility such as fog. Under such conditions light emitted in directions other than toward approaching drivers can create scattered light that makes workers and other hazards less visible. Simulations of visibility of hazards under varying conditions of fog density, forward vehicle lighting, warning beacon luminous intensity, and intensity distribution were performed to assess their impacts on visual performance by drivers. Each of these factors can influence the ability of drivers to detect and identify workers and hazards along the roadway in work zones. Based on the results, it would be reasonable to specify maximum limits on the luminous intensity of warning beacons in directions that are unlikely to be seen by drivers along the roadway, limits which are not included in published performance specifications.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1qCpRyV
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Publication date: Available online 4 January 2018 Source: European Journal of Radiology Author(s): Peiyao Zhang, Jing Wang, Qin Xu, Zhen...
-
BACKGROUND AND PURPOSE: Lesion load is a common biomarker in multiple sclerosis, yet it has historically shown modest association with cl...
-
Does CBD Oil Lower Blood Pressure? This article was originally published at SundayScaries." Madeline Taylor POSTED ON January 13, 20...
-
Despite widespread journal endorsement of reporting guidelines, the poor reproducibility of preclinical research is increasingly under debat...
-
The benefit of the breastfeeding has been well-established. In comparison to partial breast feeding, exclusive breastfeeding has even more b...
-
A report of the Cold Spring Harbor Laboratory/Wellcome Trust Meeting on Engineering Principles in Biology, Cambridge, UK, 14-16 October 2009...
-
Abstract We report here a microscopic tight-binding theoretical study of the dynamic dielectric response of graphene-on-polarizable substr...
-
Volumetry measurement of lung nodules is gaining clinical acceptance but still... Read more on AuntMinnieEurope.com Related Reading: Ul...
-
Background Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extrac...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου