Innovative use of a guideliner catheter to assist in snare retrieval of an entrapped kinked guide catheter during transradial coronary intervention

Rescue techniques that enable removal of severe intravascular catheter kinking are always worthwhile. We herein demonstrate the novel employment of a GuideLiner support catheter to assist in the removal of a kinked and entrapped guide catheter within the radial artery during coronary intervention. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bYvFgD
via IFTTT

Early or late intervention in patients with transient ST-segment elevation acute coronary syndrome: Subgroup analysis of the ELISA-3 trial

Objectives

To investigate incidence and patient characteristics of transient ST-segment elevation (TSTE) ACS and to compare outcome of early versus late invasive treatment.

Background

Optimal timing of treatment in TSTE–ACS patients is not outlined in current guidelines and no prospective randomized trials have been done so far.

Methods

Post hoc subgroup analysis of patients with TSTE randomized in the ELISA 3 trial. This study compared early (<12 h) versus late (>48 h) angiography and revascularization in 542 patients with high-risk NSTE-ACS. Primary endpoint was incidence of death, reinfarction, or recurrent ischemia at 30 days follow-up.

Results

TSTE was present in 129 patients (24.2%) and associated with male gender, smoking and younger age. The primary endpoint occurred in 8.9% of patients with and 13.0% of patients without TSTE (RR = 0.681, P = 0.214). Incidence of death or MI after 2 year follow-up was 5.7 and 14.6% respectively (RR = 0.384, P = 0.008). Within the group of patients with TSTE, incidence of the primary endpoint was 5.8% in the early and 12.7% in the late treatment group (RR = 0.455, P = 0.213), driven by reduction in recurrent ischemia. Enzymatic infarct size, bleeding and incidence of death or recurrent MI at 2 years follow-up was comparable between the treatment groups.

Conclusions

In high-risk patients with NSTE-ACS, TSTE is frequently seen. Similar to findings in patients with high-risk NSTE-ACS, immediate angiography and revascularization in these patients is feasible but not superior to later treatment. Prospective randomized trials are needed to provide more evidence in the optimal timing of treatment in patients with TSTE-ACS. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bGsnkj
via IFTTT

The impact of delirium on healthcare utilization and survival after transcatheter aortic valve replacement

Objectives

We assessed whether post-operative delirium is associated with healthcare utilization and overall survival after trans-catheter aortic valve replacement.

Background

Delirium, a common syndrome among hospitalized older adults, is associated with increased morbidity and mortality.

Methods

We reviewed 294 transcatheter aortic valve replacement cases between June 2008 and February 2015 at a tertiary care academic medical center. Post-operative delirium was identified by confusion assessment method screening and clinician diagnosis.

Results

Delirium was identified in 61 patients (21%). Non-femoral access for trans-catheter aortic valve replacement was more common in delirious patients than in non-delirious patients (41% vs. 27%, P = 0.04). Delirious patients had diminished overall survival after trans-catheter aortic valve replacement compared to non-delirious patients (1-year survival 59% vs. 84%, log-rank P = 0.002). After adjusting for age, Society of Thoracic Surgeons predicted 30-day mortality, and access type; delirium remained independently associated with diminished overall survival (hazard ratio 2.01, 95% confidence interval 1.21–3.33, P = 0.007). The delirium group had longer mean hospital stay (13.3 ± 9.5 days vs. 6.7 ± 3.8 days, P < 0.001) and a higher rate of discharge to a rehabilitation facility (61% vs. 27%, P < 0.001), but there was no difference in 30-day hospital re-admission rates or 30-day mortality based on delirium status.

Conclusions

Delirium occurs in one out of five patients after trans-catheter aortic valve replacement and is associated with diminished survival and increased healthcare utilization. Further studies are needed to clarify whether strategies aimed at reducing delirium after trans-catheter aortic valve replacement may improve outcomes in this high-risk subset. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bYv92e
via IFTTT

Relative prosthesis-patient mismatch after transcatheter aortic valve replacement: The impact of morbid obesity

Prosthesis-patient mismatch (PPM) is defined as a small effective orifice area (EOA) of a normally functioning prosthetic valve in relation to patient body size. Even moderate impediment to forward flow has been associated with an increase in all-cause mortality. We report an unusual cause of PPM where a transcatheter implantation of a large EOA valve in an aortic position results in relative PPM in a patient with morbid obesity. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bGrzfc
via IFTTT

First prospective multicenter experience with the 7 French Glidesheath slender for complex transradial coronary interventions

Purpose

To assess the feasibility and safety of the 7 French (Fr) Glidesheath Slender for complex transradial (TR) percutaneous coronary interventions (PCI).

Background

The TR approach is increasingly used worldwide for coronary and peripheral vascular interventions. However, the small size of the radial artery remains an important limitation for the use of large-bore guiding catheters (>6 Fr), restricting thereby the treatment of highly complex lesions through the TR approach. The 7 Fr Glidesheath slender (Terumo, Tokyo, Japan) is a new dedicated radial sheath with a thinner wall and hydrophilic coating. It combines an inner diameter compatible with any 7 Fr guiding catheter and an outer diameter smaller than current 7 Fr sheaths.

Methods

Prospective multicenter registry of complex TR PCI cases using the 7 Fr Glidesheath Slender to determine the procedural success, rates of vascular complications, radial spasm, and radial artery occlusion (RAO).

Results

A total of 60 patients were included. Procedural success was 97% with only one access-site crossover. The use of a 7 Fr guiding catheter was indicated for the treatment of highly complex coronary lesions including distal left main (LM) disease (n = 20), complex non-LM bifurcation lesions (n = 16), chronic total occlusion (n = 15), and severely calcified vessels requiring rotational atherectomy (n = 10). There were three vascular access-site complications (4.7%) including two moderate (type II) local hematoma and one uncomplicated guiding catheter-induced brachial artery dissection. None of the patients experienced major bleeding. The occurrence of radial spasm was reported in seven patients (11%). Doppler ultrasound imaging of the radial artery at 1 month was available in 62 of 64 radial access with three cases of RAO (4.8%).

Conclusions

Use of the 7 Fr Glidesheath slender for complex coronary interventions is feasible and associated with a high rate of procedural success and a low rate of vascular complications. These favorable results need be confirmed in larger multicenter studies. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bYv528
via IFTTT

Left atrial appendage closure: A single center experience and comparison of two contemporary devices

Objectives

To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a “real-world” population.

Background

Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared.

Methods

We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed.

Results

One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 6–26 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks ≥1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices.

Conclusions

Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bGrsQV
via IFTTT

Defining the common femoral artery: Insights from the femoral arterial access with ultrasound trial

Objective

We sought to establish the typical location of the common femoral artery (CFA) bifurcation, the origin and most inferior reflection of the inferior epigastric artery (IEA) relative to the femoral head (FH) and whether patient demographics predicted anatomical variations.

Background

In the absence of ultrasound guidance or prior imaging, the precise location of the CFA bifurcation and IEA can only be determined following access site angiography. Fluoroscopic landmarks are commonly used to estimate the location of the CFA bifurcation, but the position of the IEA is less well characterized.

Methods

Prospectively collected data on 989 patients with femoral angiography in the FAUST trial were analyzed. The level of CFA bifurcation and the origin and most inferior reflection of the IEA were classified by angiography. Logistic regression was used to explore whether baseline demographics were associated with anatomic variations.

Results

The CFA bifurcation occurs below the middle 1/3rd of the femoral head in 95% of patients, and no patient factors are predictive of a high bifurcation. The IEA origin has a more variable anatomically pattern, with high BSA, male gender, and white race associated with a low IEA origin.

Conclusion

Operators should attempt to access the CFA at the level of the middle 1/3rd of the FH to maximize the chance of CFA cannulation. However, this location carries an 11% risk of being at or above the IEA origin. Baseline demographics were of limited utility for predicting anatomic variants of the CFA bifurcation and the course of the IEA. © 2016 Wiley Periodicals, Inc.



from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2bYuCNI