Δευτέρα 16 Απριλίου 2018

Magnetic resonance imaging during management of patients with transfusion-dependent thalassemia: a single-center experience

Abstract

Background

Cardiac and hepatic magnetic resonance imaging evaluation during treatment can tailor physicians' chelation therapy titrations.

Aim

The aim of the study was to assess the relationship of cardiac and hepatic T2* values with chelation therapy in patients with transfusion-dependent thalassemia (TDT).

Methods

A total of 106 patients with TDT who were followed up in Istanbul Medical Faculty Thalassemia Center were evaluated for the study. Forty-eight (45%) patients with TDT had more than one consecutive MRI examination. The patients were divided into three subgroups according to the cardiac T2* values as the high-risk group (T2* MRI < 10 ms), medium-risk group (T2* MRI 10-20 ms), and the low-risk group (T2* MRI > 20 ms).

Results

The majority of patients used DFX (deferasirox) (79%) and deferiprone (DFP) (17%). Approximately 80% of patients according to cardiac T2* value and 40% of patients according to hepatic T2* value were initially in the low-risk group. Patients with follow-up MRI examinations exhibited significant improvement in liver iron concentration, which correlated with an increase in hepatic T2* values. The decrease of liver iron concentration was prominent in the DFX group (p < 0.01). The serum ferritin level was significantly correlated with liver iron concentrations (rs = 0.65, p < 0.001), hepatic T2* value (rs = − 0.62, p < 0.001), but not with cardiac T2* value (rs = − 0.20, p = 0.07).

Conclusion

Cardiovascular and hepatic MRI is a useful follow-up tool during the assessment of risk groups and chelation therapy of patients with TDT. Consecutive MRI tests showed good monitoring of cardiac and liver iron overload.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2qwECqj

Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures

Abstract

Purpose

Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method.

Methods

A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ( \(n=9\) ) or retrospective clinical ( \(n=1\) ) EUS landmarks.

Results

The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value \(< 0.01\) ).

Conclusions

The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2HtloLM

Mandibular canal branching assessed with cone beam computed tomography

Abstract

Purpose

The mandibular canal must be considered in dental procedures to avoid injuries of the alveolar inferior nerve. The occurrence of anatomical variations of the mandibular canal increases the risk of neurovascular injuries. The purpose of this study was to identify and describe the prevalence of mandibular canal branching (MCB) using cone beam computer tomography (CBCT).

Methods

Seven hundred standardized CBCTs were selected. The images were evaluated for the presence of MCB and for the detection of pathologies that could affect the structure of the canals. The data were analyzed using descriptive statistics and the Chi-squared test.

Results

The prevalence of MCB was 41.1%. There was no statistical difference between genders with the presence of the branches (p > 0.005). The highest prevalence was in the premolar and retromolar regions. Pathologies found in the molar region were frequently connected with MCB (77.8%), and the most common pathology related to branches was periapical lesion.

Conclusions

Mandibular canal branching presented a high prevalence in CBCT imagery, more frequently located in regions of the premolar and retromolar. An adequate diagnosis of the MCB is necessary to perform dental procedures and verify possible associated pathologies.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2qCsWBr

MRI patient selection for endovascular thrombectomy in acute ischemic stroke: correlation between pretreatment diffusion weighted imaging and outcome scores

Abstract

Introduction

Eligibility for endovascular treatment (EVT) in patients with acute ischemic stroke (AIS) depends, amongst other factors, on CT- or MR-based scores. The aim of this study was to investigate the role of Alberta Stroke Program Early CT score based on diffusion weighted imaging (MR-ASPECT) in the assessment of brain damage pre-EVT, patient selection for EVT and outcome.

Materials and methods

We included in this study patients with National Institute of Health stroke score (NIHSS) at admission ≥ 8, MR-ASPECT ≥ 5 and anterior AIS, who were treated with EVT in our hospital. All patients were clinically evaluated at admission, post-EVT, discharge and at 3-month follow-up. We used MR-ASPECT to establish infarct core extension at admission. We evaluated ASPECT score at admission (CT-ASPECT-IN), 24 h after EVT and at discharge, NIHSS, modified Ranking Scale (mRS), Thrombolysis in Cerebral Infarction scale (TICI), onset-to-intervention-delay (OTID) and Collateral Circulation Score (CCS).

Results

68 patients (mean age 78 ± 11.9 years) were included in this study. 54.4 and 64.7% of patients had strong clinical improvement after 24 h from EVT and at discharge, respectively. NIHSS evaluated 24 h after EVT correlated with CCS, TICI and OTID. We observed a favourable outcome (mRS 0–2) in 52.9% of patients at 3-month follow-up. MR-ASPECT score correlated with post-EVT outcome better than CT-ASPECT-IN scores.

Conclusion

MR-ASPECT score based on diffusion weighted imaging is useful for the selection of patients with AIS that can have a favourable outcome from EVT. A prompt EVT has huge impact on patient outcome.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2H3JUUi

Septo-optic Dysplasia

Abstract

Purpose

Septo-optic dysplasia is a congenital disorder consisting of optic nerve hypoplasia and absent septum pellucidum. While associated anomalies have been described, olfactory sulcus and bulb-tract hypoplasia have been scantily reported and was the focus of this study.

Methods

The picture archival and communications system and radiology information system (PACS-RIS) was searched over 15 years for patients with suspected septo-optic dysplasia (n= 41) and cerebral magnetic resonance imaging (MRI). Included patients had coronal (≤3 mm), axial (≤4 mm), and sagittal (≤4 mm) imaging reviewed by two staff neuroradiologists by consensus. Both olfactory sulcus and bulb-tract hypoplasia were ascribed a grade of 0 (normal) to 3 (complete hypoplasia). Other associated congenital anomalies were recorded, if present. Incidence of anomalies were compared to age-matched and gender-matched control patients.

Results

Out of 41 septo-optic dysplasia patients 33 were included (mean age = 120.7 months), with 8 excluded due to isolated septum pellucidum absence (n= 5), isolated bilateral optic hypoplasia (n= 2), or inadequate imaging (n= 1). An olfactory sulcus was hypoplastic on one or both sides in 14/33 (42.4%). Olfactory bulb hypoplasia was noted in one or both tracts in 15/33 (45.4%). A significant correlation was found between degree of olfactory sulcal and bulb-tract hypoplasia (ρ = 0.528, p= 0.0009). Other anomalies were: anterior falx dysplasia (n= 16, 48.5%), incomplete hippocampal inversion (n= 14, 42.4%), polymicrogyria (n= 11, 33.3%), callosal complete or partial agenesis (n = 10, 30.3%), schizencephaly (n = 8, 24.2%), ectopic posterior pituitary (n= 6, 18.2%), and nodular heterotopia (n= 4, 12.1%). Of the age-matched control patients 10/33 (30.3%) had at least mild anterior falx hypoplasia, and 1 control patient was noted to have unilateral incomplete hippocampal inversion (IHI); none of the age-matched control patients had olfactory sulcus or bulb-tract hypoplasia.

Conclusion

Olfactory sulcus and bulb-tract hypoplasia are fairly common in septo-optic dysplasia and can be discordant between sides. Of the other associated anomalies, anterior falx dysplasia seems to be the most common.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2IVrmlC

In vivo estimation of target registration errors during augmented reality laparoscopic surgery

Abstract

Purpose

Successful use of augmented reality for laparoscopic surgery requires that the surgeon has a thorough understanding of the likely accuracy of any overlay. Whilst the accuracy of such systems can be estimated in the laboratory, it is difficult to extend such methods to the in vivo clinical setting. Herein we describe a novel method that enables the surgeon to estimate in vivo errors during use. We show that the method enables quantitative evaluation of in vivo data gathered with the SmartLiver image guidance system.

Methods

The SmartLiver system utilises an intuitive display to enable the surgeon to compare the positions of landmarks visible in both a projected model and in the live video stream. From this the surgeon can estimate the system accuracy when using the system to locate subsurface targets not visible in the live video. Visible landmarks may be either point or line features. We test the validity of the algorithm using an anatomically representative liver phantom, applying simulated perturbations to achieve clinically realistic overlay errors. We then apply the algorithm to in vivo data.

Results

The phantom results show that using projected errors of surface features provides a reliable predictor of subsurface target registration error for a representative human liver shape. Applying the algorithm to in vivo data gathered with the SmartLiver image-guided surgery system shows that the system is capable of accuracies around 12 mm; however, achieving this reliably remains a significant challenge.

Conclusion

We present an in vivo quantitative evaluation of the SmartLiver image-guided surgery system, together with a validation of the evaluation algorithm. This is the first quantitative in vivo analysis of an augmented reality system for laparoscopic surgery.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2qBEhSu

Fiducial-based fusion of 3D dental models with magnetic resonance imaging

Abstract

Purpose

Magnetic resonance imaging (MRI) is widely used in study of maxillofacial structures. While MRI is the modality of choice for soft tissues, it fails to capture hard tissues such as bone and teeth. Virtual dental models, acquired by optical 3D scanners, are becoming more accessible for dental practice and are starting to replace the conventional dental impressions. The goal of this research is to fuse the high-resolution 3D dental models with MRI to enhance the value of imaging for applications where detailed analysis of maxillofacial structures are needed such as patient examination, surgical planning, and modeling.

Methods

A subject-specific dental attachment was digitally designed and 3D printed based on the subject's face width and dental anatomy. The attachment contained 19 semi-ellipsoidal concavities in predetermined positions where oil-based ellipsoidal fiducial markers were later placed. The MRI was acquired while the subject bit on the dental attachment. The spatial position of the center of mass of each fiducial in the resultant MR Image was calculated by averaging its voxels' spatial coordinates. The rigid transformation to fuse dental models to MRI was calculated based on the least squares mapping of corresponding fiducials and solved via singular-value decomposition.

Results

The target registration error (TRE) of the proposed fusion process, calculated in a leave-one-fiducial-out fashion, was estimated at 0.49 mm. The results suggest that 6–9 fiducials suffice to achieve a TRE of equal to half the MRI voxel size.

Conclusion

Ellipsoidal oil-based fiducials produce distinguishable intensities in MRI and can be used as registration fiducials. The achieved accuracy of the proposed approach is sufficient to leverage the merged 3D dental models with the MRI data for a finer analysis of the maxillofacial structures where complete geometry models are needed.



from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2qA5Mwy