Τετάρτη 8 Νοεμβρίου 2017

Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR

Abstract

Purpose

Recent studies have shown an excellent correlation between PET/MR and PET/CT hybrid imaging in detecting lesions. However, a systematic underestimation of PET quantification in PET/MR has been observed. This is attributable to two methodological challenges of MR-based attenuation correction (AC): (1) lack of bone information, and (2) truncation of the MR-based AC maps (μmaps) along the patient arms. The aim of this study was to evaluate the impact of improved AC featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR.

Methods

The MR-based Dixon method provides four-compartment μmaps (background air, lungs, fat, soft tissue) which served as a reference for PET/MR AC in this study. A model-based bone atlas provided bone tissue as a fifth compartment, while the HUGE method provided truncation correction. The study population comprised 51 patients with oncological diseases, all of whom underwent a whole-body PET/MR examination. Each whole-body PET dataset was reconstructed four times using standard four-compartment μmaps, five-compartment μmaps, four-compartment μmaps + HUGE, and five-compartment μmaps + HUGE. The SUVmax for each lesion was measured to assess the impact of each μmap on PET quantification.

Results

All four μmaps in each patient provided robust results for reconstruction of the AC PET data. Overall, SUVmax was quantified in 99 tumours and lesions. Compared to the reference four-compartment μmap, the mean SUVmax of all 99 lesions increased by 1.4 ± 2.5% when bone was added, by 2.1 ± 3.5% when HUGE was added, and by 4.4 ± 5.7% when bone + HUGE was added. Larger quantification bias of up to 35% was found for single lesions when bone and truncation correction were added to the μmaps, depending on their individual location in the body.

Conclusion

The novel AC method, featuring a bone model and truncation correction, improved PET quantification in whole-body PET/MR imaging. Short reconstruction times, straightforward reconstruction workflow, and robust AC quality justify further routine clinical application of this method.



from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zuJ7VD

Dual energy computed tomography for the head

Abstract

Dual energy CT (DECT) is a promising technology that provides better diagnostic accuracy in several brain diseases. DECT can generate various types of CT images from a single acquisition data set at high kV and low kV based on material decomposition algorithms. The two-material decomposition algorithm can separate bone/calcification from iodine accurately. The three-material decomposition algorithm can generate a virtual non-contrast image, which helps to identify conditions such as brain hemorrhage. A virtual monochromatic image has the potential to eliminate metal artifacts by reducing beam-hardening effects. DECT also enables exploration of advanced imaging to make diagnosis easier. One such novel application of DECT is the X-Map, which helps to visualize ischemic stroke in the brain without using iodine contrast medium.



from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2Awt8GG

Heterogeneity of longitudinal and circumferential contraction in relation to late gadolinium enhancement in hypertrophic cardiomyopathy patients with preserved left ventricular ejection fraction

Abstract

Purpose

To evaluate heterogeneity of myocardial contraction in relation to extensive late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM) patients with preserved left ventricular ejection fraction, using fast strain-encoded magnetic resonance imaging.

Materials and methods

Twenty-two HCM patients and 24 age-matched control subjects were included in this retrospective study. The regional and global peak values of longitudinal and circumferential strain (LSregional, LSglobal, CSregional, CSglobal), and their regional heterogeneities were evaluated using coefficients of variation (LSCoV, CSCoV) in relation to LGE. Receiver operating characteristic curve analysis was performed to identify patients with a total left ventricular myocardial LGE ≥ 15%.

Results

LSglobal in HCM patients was significantly decreased compared to that in controls (− 14.4 ± 2.4% vs − 17.2 ± 2.0%; p = 0.0004), while CSglobal was not (p = 1.0). Negative LGE segments demonstrated decreased LSregional in HCM patients compared to in controls (p < 0.0001), while CSregional was not decreased. CSCoV demonstrated the largest area under the curve (AUC) (0.91), with high sensitivity (83%) and specificity (94%) for detection of HCM patients with extensive LGE, while the AUC of LSCoV was low (0.49).

Conclusion

The heterogeneity in CSregional has a high diagnostic value for detection of HCM patients with extensive LGE.



from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2yizpV0

Marine radioecology after the Fukushima Dai-ichi nuclear accident: Are we better positioned to understand the impact of radionuclides in marine ecosystems?

Publication date: 15 March 2018
Source:Science of The Total Environment, Volume 618
Author(s): J. Vives i Batlle, M. Aoyama, C. Bradshaw, J. Brown, K.O. Buesseler, N. Casacuberta, M. Christl, C. Duffa, N.R.E.N. Impens, M. Iosjpe, P. Masqué, J. Nishikawa
This paper focuses on how a community of researchers under the COMET (CO-ordination and iMplementation of a pan European projecT for radioecology) project has improved the capacity of marine radioecology to understand at the process level the behaviour of radionuclides in the marine environment, uptake by organisms and the resulting doses after the Fukushima Dai-ichi nuclear accident occurred in 2011. We present new radioecological understanding of the processes involved, such as the interaction of waterborne radionuclides with suspended particles and sediments or the biological uptake and turnover of radionuclides, which have been better quantified and mathematically described.We demonstrate that biokinetic models can better represent radionuclide transfer to biota in non-equilibrium situations, bringing more realism to predictions, especially when combining physical, chemical and biological interactions that occur in such an open and dynamic environment as the ocean. As a result, we are readier now than we were before the FDNPP accident in terms of having models that can be applied to dynamic situations.The paper concludes with our vision for marine radioecology as a fundamental research discipline and we present a strategy for our discipline at the European and international levels. The lessons learned are presented along with their possible applicability to assess/reduce the environmental consequences of future accidents to the marine environment and guidance for future research, as well as to assure the sustainability of marine radioecology. This guidance necessarily reflects on why and where further research funding is needed, signalling the way for future investigations.

Graphical abstract

image


from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2m6zn0N

Radionuclide concentration processes in marine organisms: A comprehensive review

Publication date: Available online 8 November 2017
Source:Journal of Environmental Radioactivity
Author(s): Fernando P. Carvalho
The first measurements made of artificial radionuclides released into the marine environment did reveal that radionuclides are concentrated by marine biological species. The need to report radionuclide accumulation in biota in different conditions and geographical areas prompted the use of concentration factors as a convenient way to describe the accumulation of radionuclides in biota relative to radionuclide concentrations in seawater. Later, concentration factors became a tool in modelling radionuclide distribution and transfer in aquatic environments and to predicting radioactivity in organisms. Many environmental parameters can modify the biokinetics of accumulation and elimination of radionuclides in marine biota, but concentration factors remained a convenient way to describe concentration processes of radioactive and stable isotopes in aquatic organisms. Revision of CF values is periodically undertaken by international organizations, such as the International Atomic Energy Agency (IAEA), to make updated information available to the international community. A brief commented review of radionuclide concentration processes and concentration factors in marine organisms is presented for key groups of radionuclides such as fission products, activation products, transuranium elements, and naturally-occurring radionuclides.



from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2hTM629

Analysis of Contaminated Nuclear Plant Steel by Laser-Induced Breakdown Spectroscopy

Publication date: Available online 7 November 2017
Source:Journal of Hazardous Materials
Author(s): Adam Lang, Dirk Engelberg, Nicholas T. Smith, Divyesh Trivedi, Owen Horsfall, Anthony Banford, Philip A. Martin, Paul Coffey, William R. Bower, Clemens Walther, Martin Weiß, Hauke Bosco, Alex Jenkins, Gareth T.W. Law
Laser Induced Breakdown Spectroscopy (LIBS) has the potential to allow direct, standoff measurement of contaminants on nuclear plant. Here, LIBS is evaluated as an analytical tool for measurement of Sr and Cs contamination on type 304 stainless steel surfaces. Samples were reacted in model acidic (PUREX reprocessing) and alkaline (spent fuel ponds) Sr and Cs bearing liquors, with LIBS multi-pulse ablation also explored to measure contaminant penetration. The Sr II (407.77nm) and Cs I (894.35nm) emission lines could be separated from the bulk emission spectra, though only Sr could be reliably detected at surface loadings > 0.5mg cm−2. Depth profiling showed decay of the Sr signal with time, but importantly, elemental analysis indicated that material expelled from LIBS craters is redistributed and may interfere in later laser shot analyses.



from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2m6zfhP

A prospective evaluation of hippocampal radiation dose volume effects and memory deficits following cranial irradiation

To prospectively evaluate hippocampal radiation dose volume effects and memory decline following cranial irradiation.

from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2Aln6Yq

Δημοφιλείς αναρτήσεις