Publication date: Available online 13 April 2018
Source:European Journal of Radiology
Author(s): Xue-Mei Zhao, Man Wang, Run-Ze Wu, Ekta Dharaiya, Feng Feng, Ming-Li Li, Hui You, Yun Wang, Zheng-Yu Jin, Yi-Ning Wang
PurposeTo investigate and compare image quality of monoenergetic reconstructions from spectral NCCT to conventional 120kVp images acquired at a similar dose.Materials and methodsPatients undergoing NCCT on a dual-layer spectral detector CT (n = 30) and a conventional CT (n = 30) were enrolled in the study. The spectral detector CT data was reconstructed at monoenergetic images from 40–140 keV in 5-keV increments and 65–70 keV in 1-keV increments (Group A1) and using single energy CT equivalent reconstruction (Group A2). The reference conventional 120kVp images (Group B) were acquired using a standard-of-care protocol with the same radiation dose. We evaluated the image quality of monoenergetic images and determined the optimal keV level using HU attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), artifact evaluation in posterior fossa by placing region-of-interest (ROI) and subjective image score by 2 radiologists independently using a 4-point scale (1–excellent, 4–undiagnostic).ResultsThe SNR and subjective image score were optimal at 66-70keV, while monoenergetic 68 keV images with a higher SNR (18.48 ± 1.94, 15.55 ± 1.56 and 14.33 ± 1.38 for Group 68keV, A2 and B respectively, p < 0.001), CNR (4.09 ± 0.65, 3.43 ± 0.56 and 3.52 ± 0.55 for Group 68keV, A2 and B respectively, p<0.001) and a lower noise (1.80 ± 0.19, 2.11 ± 0.19 and 2.25 ± 0.25 for Group 68keV, A2 and B respectively, p<0.001).ConclusionSpectral NCCT monoenergetic reconstructions at 68 keV improve image quality and reduce artifact compared to conventional single energy CT without radiation dose penalty.
from Imaging via alkiviadis.1961 on Inoreader https://ift.tt/2qxhneO
Σάββατο 14 Απριλίου 2018
Dual-layer spectral detector CT monoenergetic reconstruction improves image quality of non-contrast cerebral CT as compared with conventional single energy CT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Essay Thesaurus Generator eisenschiml thesis Short essay on great wall of china how to start a compare and contrast essay sample assessing c...
-
Zusammenfassung Hintergrund Der Einfluss des „hospital volume" und „surgeon volume" auf das Behandlungsergebnis wird anhand de...
-
Vol.6 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kRz7Sf via IFTTT
-
This post dissects the components of a good thesis statement and gives 10 thesis statement examples to inspire your next argumentative essay...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nqJxJL via IFTTT
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oz7Jcs via IFTTT
-
Dolphins have a special way of preparing the octopuses they eat – but when that goes awry the consequences can be deadly from #AlexandrosS...
-
The Notch signaling pathway is a very conserved system that controls embryonic cell fate decisions and the maintenance of adult stem cells t...
-
Check Your Bracket Challenge Picks 👀 Bleacher Report Bracket Challenge via Bleacher Report Bracket Challenge from #AlexandrosSfakianakis ...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου