Objectives The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. Methods We performed an experimental phantom study with 4 mediastinal iodine phantoms. Each phantom contained 6 tubes of different iodine concentrations (0, 1.0, 2.5, 5.0, 10.0, and 20.0 mg/mL) diluted in a specific solvent, which was water, 10% amino acid solution, 20% lipid emulsion, or 18% calcium solution, respectively. Mediastinal phantoms were inserted into an anthropomorphic chest phantom and were scanned with 3 different DECT scanners from 3 vendors using 2 radiation dosage settings. Iodine density (IoD) and computed tomography (CT) attenuation at virtual monoenergetic 70-keV images and virtual nonenhanced images were measured for the iodine phantoms. The effects of DECT scanners, solvents, and radiation dosage on the absolute measurement error of IoD and on the CT attenuation profiles were investigated using linear mixed-effects models. Measurement variability range of IoD was also determined. Results Absolute error of IoD was not significantly affected by the DECT systems, kind of solvents, and radiation dosage settings. However, CT attenuation profiles were significantly different among the DECT vendors and simulated body fluids. Measurement variability range of IoD was from −0.6 to 0.4 mg/mL for the true iodine concentration 0 mg/mL. Conclusions Dual-energy CT systems and fluid characteristics did not have a significant effect on the IoD measurement accuracy. A cutoff of IoD for the determination of a truly enhancing lesion on DECT would be 0.4 mg/mL. Received for publication September 27, 2017; and accepted for publication, after revision, November 23, 2017. Conflicts of interest and sources of funding: none declared. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Web site (http://ift.tt/2kq7jVD). Correspondence to: Jin Mo Goo, MD, PhD, Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 110-744, Korea. E-mail: jmgoo@plaza.snu.ac.kr. Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2D6GIFD
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Introduction Crisis management is a critical organizational function. Failure can result in serious harm to stakeholders, losses for an orga...
-
Publication date: 1 July 2017 Source: Cancer Letters, Volume 397 Author(s): Makoto Sano, Yoshimi Ichimaru, Masahiro Kurita, Emiko Hayashi,...
-
Maritime Logistics • General Ship Knowledge • Seaborne Cargoes and Dangerous Goods • Cargo Planning • Marine Terminal Operations • Modal and...
-
136 Unit 6 • Cause-Effect Essays What is a great topic for a cause-effect essay? This type of essay may focus more on the causes or more on ...
-
Winners of the 13th Annual 2017 Info Security PG's Global Excellence Awards® from #AlexandrosSfakianakis via Alexandros G.Sfakianakis ...
-
Apply to 39 Fifth Third Bank Personal Banker jobs in United States on LinkedIn. Sign-up today, leverage your professional network, and get h...
-
Publication date: Available online 7 April 2017 Source: Experimental Cell Research Author(s): Guoxing Li, Huiyang Song, Weihua Yang, Shans...
-
918 quotes have been tagged as self-confidence: Edgar Allan Poe: ‘I have great faith in fools - self-confidence my friends will call it.’, R...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου