In this pilot study, a 3D printed Grade V titanium dental implant with a novel dual-stemmed design was investigated for its biocompatibility in vivo. Both dual-stemmed (n = 12) and conventional stainless steel conical (n = 4) implants were inserted into the tibial metaphysis of New Zealand white rabbits for 3 and 12 weeks and then retrieved with the surrounding bone, fixed, dehydrated, and embedded into epoxy resin. The implants were analyzed using correlative histology, microcomputed tomography, scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The histological presence of multinucleated osteoclasts and cuboidal osteoblasts revealed active bone remodeling in the stemmed implant starting at 3 weeks and by 12 weeks in the conventional implant. Bone-implant contact values indicated that the stemmed implants supported bone growth along the implant from the coronal crest at both 3- and 12-week time periods and showed bone growth into microporosities of the 3D printed surface after 12 weeks. In some cases, new bone formation was noted in between the stems of the device. Conventional implants showed mechanical interlocking but did have indications of stress cracking and bone debris. This study demonstrates the comparable biocompatibility of these 3D printed stemmed implants in rabbits up to 12 weeks.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2j7ZDmz
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Essay Thesaurus Generator eisenschiml thesis Short essay on great wall of china how to start a compare and contrast essay sample assessing c...
-
The Notch signaling pathway is a very conserved system that controls embryonic cell fate decisions and the maintenance of adult stem cells t...
-
How to write a Scholarship Essay - Examples. Scholarship Essays should use this formatting unless specified otherwise: Two to three pages in...
-
This post dissects the components of a good thesis statement and gives 10 thesis statement examples to inspire your next argumentative essay...
-
3D CAD Services Streamline Design Process. Neco Inc., of Denver, Colorado, provides 3D Computer Aided Design and support services primarily ...
-
http://ift.tt/2p7HgAl
-
Zusammenfassung Hintergrund Der Einfluss des „hospital volume" und „surgeon volume" auf das Behandlungsergebnis wird anhand de...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nqJxJL via IFTTT
-
Through the Wormhole: Is There an Edge to... Science - 43 min - ★ It is commonly theorized that the universe began with the Big Bang... Thro...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου