Publication date: December 2017
Source:European Journal of Radiology, Volume 97
Author(s): Corinne Balleyguier, Julia Arfi-Rouche, Laurent Levy, Patrick R. Toubiana, Franck Cohen-Scali, Alicia Y. Toledano, Bruno Boyer
PurposeEvaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time.Materials and methodsThe CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0–100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive.ResultsAverage AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: −0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0–37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: −0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: ‐0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a −0.014 difference (95% CI for difference: ‐0.079,0.050) and a small 0.025 increase (95% CI for difference: −0.036,0.087) in recall rate in non-cancer cases were observed with CAD.ConclusionsConcurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2zQyq1V
Σάββατο 18 Νοεμβρίου 2017
Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD)
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Introduction Crisis management is a critical organizational function. Failure can result in serious harm to stakeholders, losses for an orga...
-
Publication date: 1 July 2017 Source: Cancer Letters, Volume 397 Author(s): Makoto Sano, Yoshimi Ichimaru, Masahiro Kurita, Emiko Hayashi,...
-
Maritime Logistics • General Ship Knowledge • Seaborne Cargoes and Dangerous Goods • Cargo Planning • Marine Terminal Operations • Modal and...
-
136 Unit 6 • Cause-Effect Essays What is a great topic for a cause-effect essay? This type of essay may focus more on the causes or more on ...
-
Winners of the 13th Annual 2017 Info Security PG's Global Excellence Awards® from #AlexandrosSfakianakis via Alexandros G.Sfakianakis ...
-
918 quotes have been tagged as self-confidence: Edgar Allan Poe: ‘I have great faith in fools - self-confidence my friends will call it.’, R...
-
Apply to 39 Fifth Third Bank Personal Banker jobs in United States on LinkedIn. Sign-up today, leverage your professional network, and get h...
-
Publication date: Available online 7 April 2017 Source: Experimental Cell Research Author(s): Guoxing Li, Huiyang Song, Weihua Yang, Shans...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου