Purpose. To assess the repeatability and reproducibility of dynamic corneal response parameters measured by the Corvis ST (Oculus, Wetzlar, Germany). Methods. One eye randomly selected from 32 healthy volunteers was examined by the Corvis ST. Three different devices were used in an alternated random order for taking three measurements at each device in each subject. Standard intraocular pressure (IOP), the biomechanical-compensated IOP (bIOP), and DCR parameters were evaluated. The within-subject standard deviation (ζw) and coefficient of variation (CV) were assessed. Results. Regarding pressure indices, the ζw was below 1 mmHg for repeatability (0.98 for IOP and 0.89 for bIOP) and the CV was 6.6% for IOP and 6.1% for bIOP. For reproducibility, the ζw was around 1 mmHg (1.12 for IOP and 1.05 for bIOP) and the CV was 7.6% for IOP and 7.1% for bIOP. Most of DCR indices presented CV for repeatability below 4%. For reproducibility, the CV of most of the indices were below 6%. The deformation amplitude (DA) ratio in 1 mm and integrated radius were below 4% (1.2% and 3.8%, resp.). Conclusions. The Corvis ST showed good precision (repeatability and reproducibility) for IOP measurements and for DCR in healthy eyes.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2r0XFXh
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
How to write a Scholarship Essay - Examples. Scholarship Essays should use this formatting unless specified otherwise: Two to three pages in...
-
The Notch signaling pathway is a very conserved system that controls embryonic cell fate decisions and the maintenance of adult stem cells t...
-
Essay Thesaurus Generator eisenschiml thesis Short essay on great wall of china how to start a compare and contrast essay sample assessing c...
-
3D CAD Services Streamline Design Process. Neco Inc., of Denver, Colorado, provides 3D Computer Aided Design and support services primarily ...
-
Through the Wormhole: Is There an Edge to... Science - 43 min - ★ It is commonly theorized that the universe began with the Big Bang... Thro...
-
This post dissects the components of a good thesis statement and gives 10 thesis statement examples to inspire your next argumentative essay...
-
http://ift.tt/2p7HgAl
-
Zusammenfassung Hintergrund Der Einfluss des „hospital volume" und „surgeon volume" auf das Behandlungsergebnis wird anhand de...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nqJxJL via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου