Acquired diaphragmatic perforation leading to massive hepatic hydrothorax and respiratory failure is a rare complication of microwave ablation (MWA) of hepatocellular carcinoma (HCC). Imaging modalities to detect pleuroperitoneal communication remain poorly described. We report a nuclear imaging technique used to efficiently diagnose and locate diaphragmatic defects. A 57-year-old male with cirrhosis and HCC presented with respiratory distress after undergoing MWA of a HCC lesion. He was admitted to the intensive care unit for noninvasive positive pressure ventilator support. Chest radiography revealed a new large right pleural effusion. Large-volume thoracentesis was consistent with hepatic hydrothorax. The fluid reaccumulated within 24 hours; therefore an acquired diaphragmatic perforation induced by the ablation procedure was suspected. To investigate, Technetium-labeled albumin was injected into the peritoneal cavity. The tracer accumulated in the right hemi thorax almost immediately. The patient then underwent transjugular intrahepatic portosystemic shunting in efforts to relieve portal hypertension and decrease ascites volume. Unfortunately, the patient deteriorated and expired after few days. Although diaphragmatic defects develop in cirrhotic patients, such small fenestrations do not normally lead to rapid development of life-threatening pleural effusion. MWA procedures can cause large diaphragmatic defects. Immediate detection of this complication is essential for initiating early intervention.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2mUWGJR
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Essay Thesaurus Generator eisenschiml thesis Short essay on great wall of china how to start a compare and contrast essay sample assessing c...
-
The Notch signaling pathway is a very conserved system that controls embryonic cell fate decisions and the maintenance of adult stem cells t...
-
How to write a Scholarship Essay - Examples. Scholarship Essays should use this formatting unless specified otherwise: Two to three pages in...
-
This post dissects the components of a good thesis statement and gives 10 thesis statement examples to inspire your next argumentative essay...
-
3D CAD Services Streamline Design Process. Neco Inc., of Denver, Colorado, provides 3D Computer Aided Design and support services primarily ...
-
http://ift.tt/2p7HgAl
-
Zusammenfassung Hintergrund Der Einfluss des „hospital volume" und „surgeon volume" auf das Behandlungsergebnis wird anhand de...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nqJxJL via IFTTT
-
Through the Wormhole: Is There an Edge to... Science - 43 min - ★ It is commonly theorized that the universe began with the Big Bang... Thro...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου