by Priscilla Bento Matos Derogis, Livia Rentas Sanches, Valdir Fernandes de Aranda, Marjorie Paris Colombini, Cristóvão Luis Pitangueira Mangueira, Marcelo Katz, Adriana Caschera Leme Faulhaber, Claudio Ernesto Albers Mendes, Carlos Eduardo dos Santos Ferreira, Carolina Nunes França, João Carlos de Campos Guerra
Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, pfrom #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2jZ5FUQ