2016-12-07T07-25-15Z
Source: Medicine Science | International Medical Journal
Haluk Cabuk, Cem Dincay Buyukkurt, Suleyman Semih Dedeoglu, Yunus Imren, Ali Cagrı Tekin, Hakan Gurbuz.
Fluoroscopy is routinely used in trauma cases to evaluate alignment and reduction quality. Because conventional templating has a high mismatch rate, we sought to explore whether we could use intraoperative fluoroscopy while implanting the femoral stem. Sixty patients with Croft 3-4 coxarthrosis were included in this study. No preoperative templating was performed in either of the two groups. The final conformations of the stem sizes and positions were achieved freehand intraoperatively using anatomic landmarks. In the second group, after surgeons intraoperatively agreed on the final stem size, C-arm fluoroscopy images are obtained with the last rasp size before the stem implantation. The alignment of femoral stem according to the femoral canal, the lower leg discrepancy (LLD) and the lateral offsets were evaluated with X ray. The stem/endosteal areas at 2 cm above the trochanter minor (T+2) and 2 cm below the trochanter minor (T-2) and the deviation of the stem tip from the center of the femoral canal were evaluated in CT images. The stems that were implanted under fluoroscopic control filled the medullary cavity better at both the T+2 and T-2 levels. On fluoroscopy, in the control group, the malpositioning of the femoral stems were less, the centralizations were better, and the restorations of the lateral offset and LLD were more accurate. The use of fluoroscopy while rasping the femoral canal leads to proper alignment and press fitting of the stem and provides the opportunity to intraoperatively correct malpositionings of the stem.
http://ift.tt/2h64Sld
Τετάρτη 7 Δεκεμβρίου 2016
Fluoroscopy improves femoral stem placement in cementless total hip arthroplasty
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Essay Thesaurus Generator eisenschiml thesis Short essay on great wall of china how to start a compare and contrast essay sample assessing c...
-
Vol.6 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kRz7Sf via IFTTT
-
This post dissects the components of a good thesis statement and gives 10 thesis statement examples to inspire your next argumentative essay...
-
3D CAD Services Streamline Design Process. Neco Inc., of Denver, Colorado, provides 3D Computer Aided Design and support services primarily ...
-
Zusammenfassung Hintergrund Der Einfluss des „hospital volume" und „surgeon volume" auf das Behandlungsergebnis wird anhand de...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2nqJxJL via IFTTT
-
Check Your Bracket Challenge Picks 👀 Bleacher Report Bracket Challenge via Bleacher Report Bracket Challenge from #AlexandrosSfakianakis ...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2oz7Jcs via IFTTT
-
Dolphins have a special way of preparing the octopuses they eat – but when that goes awry the consequences can be deadly from #AlexandrosS...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου